Aastra Telecom 9480i CT Series User Manual

Page of 1184
Troubleshooting
41-001160-03, Rev 00, Releaes 2.4 
9-5
Troubleshooting
Setting Values for the Module/Debug Levels
There are 6 debug levels for the modules. Each debug level has a value you can 
use to turn individual levels ON and OFF. The following table identifies these 
debug levels and their values. The value of “1” (fatal errors) is the default setting 
for all modules.
KBD (Keyboard module)
log module kbd
NET (Network module)
log module net
PROVIS (Provisioning module)
log module provis
RTPT (Realtime Transport module)
log module rtpt
SND (Sound module)
log module snd
PROF (Profiler module)
log module prof
XML (Extension Markup Lanaguage)
log module xml
STUN (Simple Traversal of User Datagram 
Protocol (UDP) through Network Address 
Translation (NAT)
log module stun
Debug Level
Value
Fatal Errors
1 (default)
Errors
2
Warnings
4
Init
8
Functions
16
Info
32
All debug levels 
OFF
0
All Debug Levels 
ON
65535
Aastra Web UI Parameters
Configuration File Parameters