Aastra Telecom 41-001343-02 User Manual

Page of 876
Operational, Basic, and Advanced Parameters
 
A-113
41-001343-02 REV04 – 05.2014
Parameter 
use lldp elin
Configuration Files
aastra.cfg, <model>.cfg, <mac>.cfg
Description
Enables or disables the use of an Emergency Location Identification Number (ELIN) received 
from LLDP as a caller ID for emergency numbers. 
Format
Boolean
Default Value
1 (enabled)
Range
0 (disabled)
1 (enabled)
Example
use lldp elin: 0
Parameter 
lldp startinterval
Configuration Files
aastra.cfg, <model>.cfg, <mac>.cfg
Description
Aastra IP Phones have a 32 second time-out interval for listening to LLDP-MED responses 
when the phone is booting up. If LLDP-MED responses are received after this initial listening 
period, the phone will ignore the response. This "lldp startinterval" parameter can be used to 
configure the time-out interval. This parameter is only valid during the phone bootup proc-
ess.
Format
Integer
Default Value
32 (seconds)
Range
0- 65535 (seconds)
Example
lldp startinterval: 7
Parameter 
lldp optional inventory manage-
ment tlv
Configuration Files
aastra.cfg, <model>.cfg, <mac>.cfg
Description
Implements either all of the LLDP-MED Inventory Management TLV sets or none of the sets. 
Format
Integer
Default Value
1 (send all LLDP-MED Inventory Management TLV sets)
Range
0-1
0 (do not send any LLDP-MED Inventory Management TLV sets)
1 (send all LLDP-MED Inventory Management TLV sets)
Example
lldp optional inventory management tlv: 0