Siemens 20 User Manual

Page of 258
Examples and HowTos
 A31003-O1010-M100-9-76A9, 05/05/2008
4-2
HiPath 8000 - OpenStage Family, Administration Manual
  
  
  
beispiele.fm
Canonical Dialing
4.1.2
Canonical Dial Lookup
The following example shows settings suitable for recognizing incoming numbers and assign-
ing them to entries in the local phone book, and for generating correct dial strings from phone 
book entries, depending on whether the number is internal or external. 
Parameter
Example value Explanation
Local code <1>
780
Enterprise node prefix (here: Nottingham).
International code <1>
+44115943
Equivalent prefix to access numbers on this 
node from the PSTN. Here, the prefix used by 
the PSTN (DID/DDI: direct inward dialing) is 
943, which differs from the enterprise node 
prefix used within the enterprise network.
Local code <2>
722
Enterprise node prefix (here: Munich).
International code <2>
+4989722
Equivalent prefix to access numbers on this 
node from the PSTN. Here, the prefix used by 
the PSTN for direct inward dialing is identical 
to the enterprise node prefix.