Telular SX5T CDMA User Manual

Page of 44
Phonecell
®
SX5T CDMA2000
34
User Manual
Metering Pulse High Gain/Low Gain
If required for your phone system application, you may adjust the metering pulse generated by your
SX5T from high gain (default setting) to low gain. The gain values are as follows:
For 12Khz systems: 
Low gain = -2dbm (+/- 2dbm)
High gain (default) = 1dbm (+/- 2dbm)
For 16Khz systems: 
Low gain = -6dbm (+/- 2dbm)
High gain (default) = -2dbm (+/- 2dbm)
To set the metering pulse to high gain (default setting):
• From Configuration Mode, press 
.
To set the metering pulse to low gain:
• From Configuration Mode, press 
.
Local Metering Pulse Override/Polarity Reversal (SX5T-500C)
If your phone system application (PBX, Payphone, Public Calling Office) requires Polarity Reversal
instead of a metering pulse in order to initiate call billing, you may set your SX5T to generate Polarity
Reversal based on the CDMA system’s metering pulse signals.
For 12Khz systems: 
Low gain = -2dbm (+/- 2dbm)
High gain (default) = 1dbm (+/- 2dbm)
For 16Khz systems: 
Low gain = -6dbm (+/- 2dbm)
High gain (default) = -2dbm (+/- 2dbm)
To enable Local Meter Pulse Override (Polarity Reversal):
• From Configuration Mode, press 
.
To disable Local Meter Pulse Override (default setting):
• From Configuration Mode, press 
.
Note:
This advanced programming setting is available on the SX5T-500C models only.
#