Adtran 624 User Manual

Page of 264
Total Access 600 Series System Manual
Section 4  User Interface Guide
61200624L1-1B
© 2004 ADTRAN, Inc.
53
S
YSTEM
 C
ONFIG
 > M
ANAGEMENT
 > T
ELNET
 A
CCESS
 > A
CCESS
Sets 
A
CCESS
 to 
O
N
 or 
O
FF
 
to allow or block telnet access to the unit. The factory default value for this 
parameter is
 O
N
.
S
YSTEM
 C
ONFIG
 > M
ANAGEMENT
 > T
ELNET
 A
CCESS
 > A
UTHEN
 M
ETHOD
Set up the Telnet authentication method from this menu. The choices are 
L
OCAL
 P
ASSWORD
R
ADIUS
L
OCAL
/R
ADIUS
, and 
R
ADIUS
/L
OCAL
L
OCAL
/R
ADIUS
 indicates that the unit will try Local Password 
Authentication first, and if that fails, it will try Radius Authentication. 
R
ADIUS
/L
OCAL
 indicates that the unit 
will try Radius authentication first, and if that fails, it will try Local Password authentication. The default is 
L
OCAL
 
P
ASSWORD
.
S
YSTEM
 C
ONFIG
 > M
ANAGEMENT
 > T
ELNET
 P
ORT
Defines the TCP port number used when establishing a Telnet session. Normal Telnet port is 23. Enter a 
customized port number if desired. Make certain the Telnet program you use is configured for the same 
port number (if using a customized port number).
S
YSTEM
 C
ONFIG
 > M
ANAGEMENT
 > T
ELNET
 A
CCESS
 > U
SER
 L
IST
Add Telnet users and control the Telnet access conditions through this menu.
#
Display the index number of the Telnet users. Up to four users can be configured for access to the 
unit. Each user can be assigned a security level and idle time.
N
AME
The name is a text string of the user name for this session. The factory default is 
U
NASSIGNED
 in the 
N
AME
 field.You must enter a username in this field (up to 15 characters) because the Telnet entry is 
not activated until it is assigned a valid username. Editing the 
U
NASSIGNED
 default to be blank is 
allowed for a single Telnet entry; duplicate usernames are not allowed. During an active Telnet 
session the 
N
AME
 is displayed in the Telnet Information field located at the bottom of the menu 
screen.
P
ASSWORD
When the authenticating method is 
L
OCAL
 P
ASSWORD
, or 
L
OCAL
/R
ADIUS
, this text string is used for 
the password. You can enter up to 30 characters in this field. The factory default is no entry in this 
field.
I
DLE
 T
IME
 (
MINS
)
This sets the amount of time in minutes you can be idle before you are automatically logged off. The 
factory default is 
10 
MINUTES
. The range is 
TO
 255 
MINUTES
.
L
EVEL
This is the security level granted to the user. Table 3 on page 54 gives a brief description of each 
level. The factory default is 
F
ULL
.