G0637/G0638 Cyclone Dust Collector
Determining Main Line Duct Size
The general rule of thumb for a main line duct is 
that the velocity of the airflow must not fall below 
3500 FPM.
For  small/medium  sized  shops,  using  the  inlet 
size of the dust collector as the main line duct size 
will usually keep the air velocity above 3500 FPM 
and, depending on your system, will allow you to 
keep multiple branches open at one time.
For the Model G0637/G0638 this is 10". Mark your 
drawing as in 
Figure 52.
Figure 52. Main line size labeled on sketch.
��
���
���
���
���
���
���
���
���
Determining Branch Line Duct Size
The general rule of thumb for a branch line duct is 
that the velocity of the airflow must not fall below 
4000 FPM.
For  small/medium  sized  shops,  using  the  dust 
port size from the machine as the branch line duct 
size will achieve the correct velocity in most appli-
cations. However, if the dust port on the machine 
is  smaller  than  4",  make  the  branch  line  4"  and 
neck the line down right before the dust port.
Note: Systems with powerful dust collectors work 
better  if  multiple  blast  gates  are  left  open.  This 
also  allows  you  to  run  two  machines  at  once. 
Experiment  with  different  combinations  of  blast 
gates open/closed to find the best results for your 
system.
Write  your  determined  branch  line  sizes  on  your 
drawing, as shown in 
Figure 53.
Figure 53. Branch line sizes labeled on sketch.
��
���
���
���
���
���
���
���
���
��
��
��
��
��
��
��
A few frequently asked questions when deter-
mining branch line sizes:
What size of branch line do I use if the machine 
has two dust ports?
Simply add the total CFM given for each size from 
Figure 49 and refer to that CFM number in Figure 
54. Then, split the branch line just before the dust 
ports with matching duct sizes.
How do I manage two machines on the same 
branch line?
You have two options: 
1.  If both machines will be running at the same 
time,  add  the  total  CFM  given  for  each  size 
from 
Figure  49  and  match  the  branch  line 
given in 
Figure 54.
2.  If both the machines will never be run at the 
same  time,  reference  the  machine  with  big-
gest  dust  port  in 
Figure  54  and  add  blast 
gates  after  the  Y-branch  to  open/close  the 
line to each machine.
Total CFM
Branch Line Size
600
5"
700
5"
800
6"
1000
6"
1200
7"
1400
8"
1600
8"
Figure 54. Branch line sizing chart by total CFM 
(for use when multiple machines share line).