DBS-2.3/9.2-300
DBS Manual - Revised April 2000
  7-3
Electrical Characteristics
Table 7-1.  Input power
Table 7-2.  Power consumption and heat generation
Table 7-3.  Battery backup capacity
Equipment
Power Requirements
All DBS cabinets
120V AC 
± 10 %
 
60 
Hz 
DBS key phones
3 watts maximum (powered from the DBS)
System
Status
DB
S 4
0
DB
S 7
2
DB
S 9
6
D
B
S 40 +
DB
S 4
0
D
B
S 72 +
DB
S 4
0
D
B
S 72 +
DB
S 7
2
D
B
S 96 +
DB
S 4
0
D
B
S 96 +
DB
S 7
2
D
B
S 96 +
DB
S 9
6
Power Consumption (in Watts)
With 
no 
traffic
170 250 320 340 420 500 490 570 640 
With 
max. 
traffic
216 324 444 432 540 648 660 768 888 
Heat Generation (Btu per hour)
With no traffic
580 
853 
1092
1160
1433
1706
1672
1945
2184
With max. traffic
737
1106
1515
1474
1843
2212
2253
2621
3031
System
Battery Pack
Capacity (with maximum traffic)
DBS 40
VB-43130
40 minutes 
DBS 72
VB-43130
40 minutes
DBS 96
VB-43130
30 minutes