Chapter 4. Trunks and Lines
 Section 300-Installation
4-10
DBS Manual - Revised April 2000
DBS-2.3/9.2-300
Installation
1.  Install the G-TRK/8 or DID card in a trunk slot. 
2.  Connect the power supply by cabling the positive side to the SG 
Note: Use cables that are 18 AWG or larger to connect the power supply 
to the DBS.
Figure 4-4. -48Vpower supply installation
3.  Ground the positive side of the -48V power supply to the building 
ground.
Note: Resistance to ground must be 10 Ohms or less, and the ground 
cable must be 18 AWG or larger.
4.  Install power-surge protectors between the wall outlet and the -48V 
power supply.
5.  Use a standard 50-pin cable to connect the trunks from the MDF to the 
main trunk connector CN1.
6.  Use a test set to verify the polarity of the trunk. 