 Connecting CS 1000E system components
 Page 107 of 488
Communication Server 1000E
Installation and Configuration
cards and passes these events to the CS 1000E Core Call Server, where the 
high-level call processing decisions are made. See Figure 29 on page 107 for 
an example MG 1000E operation. 
Figure 29
MG 1000E operation
Follow Procedure 14 to connect the CS 1000E Core Call Servers to an 
MG 1000E.
Procedure 14
Connecting the CS 1000E Core Call Servers to an MG 1000E
1
Connect the CAT5 RJ-45 ELAN 1 port on Call Server 0 to the BayStack 
470. 
2
Connect the CAT5 RJ-45 ELAN 1 port on Call Server 1 to the BayStack 
470-24T.
3
Connect port 1 of the MG 1000E 100BaseT daughterboard #2 to the 
bulkhead connector #1, as shown in Figure 30 on 
. Connect the 
100BaseT Port 1 at the back of the Media Gateway to the BayStack 470. 
Refer to Figure 31 on 
 for the location of the 100BaseT port.
 
 
1,3
5
6
9
MG 1000E Example - Digital set calls IP Phone
1.  Digital set goes off-hook; off-hook message to CS.
2.  CS tells MG 1000E to provide dial tone to set.
3.  Digital set presses digit keys; messages to CS for each.
4.  CS tells MG 1000E to play ringback tone to set and allocates DSP channel.
5.  CS tells IP Phone to ring via SS.
6.  IP phone goes off-hook to answer; message to SS/CS.
7.  CS tells MG 1000E to connect set to DSP and IP phone.
8.  CS requests media between DSP and IP phone.
9.  Media path flows between DSP and IP phone.
MG 1000E
Digital set
2,4,7,8
Call Server 0
Sig Server
(SS)
15,000 +
Desktop Clients
QOS IP
WAN