Nortel Networks 1000E User Manual

Page of 490
 Installing software on the CS 1000E
 Page 151 of 488
Communication Server 1000E
Installation and Configuration
Switch call processing
Procedure 32
Switching call processing
End of Procedure
Perform a customer backup data dump (installation release)
Procedure 33
Performing a data dump to backup the customer database:
1
Log in to the system.
2
Insert a CF card into the active Call Server RMD slot to back up the 
database.
3
Load the Equipment Data Dump Program (LD 43). At the prompt, enter:
4
When “EDD000” appears on the terminal, enter: 
LD 135
Load program
SCPU
Switch call processing from Call Server 0 
to Call Server 1
Call Server 1 is now the active call processor.
LD 43
Load program.
.
EDD
EDD
Begin the data dump.
CAUTION — Service Interruption
Loss of Data
If the data dump is not successful, do not continue; 
contact your technical support organization. A data 
dump problem must be corrected before proceeding.