Nortel Networks 1000E User Manual

Page of 490
Page 214 of 488
 Configuring the CS 1000E Call Server
553-3041-210 Standard 4.00 September 2007
Configuring Digitone Receivers
Digitone Receivers must be configured in each MG 1000E if any analog 
terminals or trunks are equipped. The loop of the Digitone Receivers is the 
ZONE0
0-255
First MG 1000E zone number
VXTC0
l x
First MG 1000E Virtual conference circuit starting loop 
number. Two consecutive VXCTs are assigned. 
The VXCTs must be previously configured in LD 17.
Where:
l = 0-252
x = 0 means 1 TDS loop only.
x = 1 means 1 TDS loop and 1 conference loop.
x = 2 means 2 TDS loops and 2 conference loops.
x = 3 means 2 TDS loops and 3 conference loops.
x = 4 means 2 TDS loops and 4 conference loops.
Precede with X to remove.
IPR1
xx.xx.xx.xx
IP address of second MG 1000E cabinet uplink IP address; 
<cr> to skip to IPR2 when configuring new superloop.
ZONE1
0-255
Second MG 1000E zone number
VXCT1
l x
Second MG 1000E 
Virtual conference circuit starting loop 
number. Two consecutive VXCTs are assigned.
The VXCTs must be previously configured in LD 17.
Where:
l = 0-252
x = 0 means 1 TDS loop only.
x = 1 means 1 TDS loop and 1 conference loop.
x = 2 means 2 TDS loops and 2 conference loops.
x = 3 means 2 TDS loops and 3 conference loops.
x = 4 means 2 TDS loops and 4 conference loops.
Precede with X to remove.
LD 97 – Configuring the MG 1000E ports (Part 2 of 2)
Prompt
Response
Comment