DKS Enterprises 1808 User Manual

Page of 55
 
 
SECTION 1 - INSTALLATION 
 
Order your telephone line at least two weeks prior to the planned installation date.  This will assure 
that a phone line is available when the unit is installed.  The telephone company will require the 
following information from you: 
 
Type: 
Touch Tone, Loop Start 
Ringer Equivalence: 
0.0 A 
Jack Type: 
RJ11C 
FCC Registration (US): 
DUF6VT-12874-OT-T 
DOC (Canada): 
1736 4528 A 
Electrical Listing: 
Complies with U.L. 294 - ETL Listed 
 
CALLER ID:  You may want to consider ordering caller ID blocking from the telephone company for 
the entry system phone line.  Without caller ID blocking, tenants with the proper phone equipment will 
be able to identify the telephone number that the entry system is installed on.  This may or may not 
be desirable. 
 
1.  Open the cabinet of the telephone entry system and disconnect the keypad ribbon cable 
from the main circuit board. 
2.  Remove the 6-32 x 1/2 round head screws from the upper corners of the circuit board. 
3.  Remove the circuit board by gently pulling it out of the main terminal edge connector.  
CAUTION - the circuit board contains static sensitive components.  Discharge any static 
electricity from your hands by touching a proper ground device before removing the 
circuit board.  Place the circuit board where it will not be damaged. 
4.  Mount the cabinet of the telephone entry system.  Be sure that mounting screws do not 
protrude into the cabinet where they could cause a short on the back of the circuit board.  
Make any necessary conduit connections. 
5.  Route wiring into the cabinet.  Do not apply any power at this time.  
6.  Clean out the cabinet.  Be sure that all dirt, metal and/or wood debris is removed from the 
cabinet and that the terminal strip edge connector is clean and free of any loose particles. 
7.  Re-install the circuit board into the cabinet by gently pushing the circuit board terminals 
into the edge connector.  CAUTION - the circuit board contains static sensitive 
components.  Discharge any static electricity from your hands by touching a proper 
ground device before removing the circuit board.  
8.  Secure the circuit board to the cabinet using the screws removed in step 2. 
9.  Plug the keypad ribbon cable into the circuit board.  The cable points down. 
 
1.1 INSTALLATION 
GUIDELINES 
– ALL SYSTEMS