2.3.2  Controlling a Gate Operator and Pedestrian Gate (or Door) 
When controlling a gate operator and pedestrian gate (or door), relay 1 is typically used to control the 
gate operator while relay 2 is typically used to control the door or pedestrian gate.  Note that the 
electric strike and the magnetic lock are powered from their own power supply.  The normally open 
(NO) contact is used for electric strikes and the normally closed (NC) contact is used for magnetic 
locks. 
A variation of this diagram is for the system to control two doors or two gates. 
 
 
10  Relay 1 Common
11  Relay 1 Normally Closed
12  Relay 1 Normally Open
M a i n
T e r m i n a l
Strip
Relay 2 Common
Relay 2 Normally Closed
Relay 2 Normally Open
Relay 2 Terminal
C o n n e c t i o n s
Electric
Strike
M a g n e t i c
L o c k
G a t e
O p e r a t o r
A N D
O R