Precor p20 User Manual

Page of 108
Setting Up the Console 
19
 
 
 
Event Log 
The software is able to detect a variety of events. The event 
log holds a maximum of 30 events. After the log reaches 30 
events, older events are erased to make room for newer ones.   
Note: There is a shortcut for quick access to the Event Log 
report. From the Welcome banner, press 
Reset (Pause/Reset 
on tread consoles)
 for five seconds. If there are no events, the 
words 
STUCK KEY appear and then the console returns to 
the Welcome banner. 
Each event log entry contains the following information: 
 
Event number 
 
Odometer value when the event occurred 
 
Hour meter value at the time the event occurred 
 
Current drawn by the motor when the event occurred 
(treadmill only) 
The following table contains a list of events detectable by the 
software. 
Table  2.  Event log numbers and descriptions 
Event 
Number 
Description of Event 
00 
Upper PCA memory location event 
02 
RAM location event 
03 
EEPROM checksum event 
05 
Depressed key at power up 
09 
Lower PCA memory test event 
10 
Line Frequency out of acceptable range 
11 
Watchdog (Upper PCA) low voltage power 
12 
Watchdog (Lower PCA) low voltage power 
13 
Fan at incorrect speed (version 1 treadmills) 
14 
Fan fail (Lower PCA) 
15 
AC input voltage too high 
16 
AC input voltage too low 
20 
Too many maximum power requests in one second 
21 