Vidikron vision70 User Manual

Page of 90
Vidikron Vision 70 Series Owner’s Operating Manual
65 
PRE
L
IMINAR
Y
Colors in the image are 
swapped; for example, reds 
appear blue or vice versa. 
The Red/Pr, Green/Y or 
Blue/Pb outputs from the 
source are connected to the 
wrong inputs on the Vision 
70.
Ensure that the source 
outputs are connected to 
the correct Vision 70 input. 
TEMP and LAMP LEDs are both 
flashing red. 
The lamp cover is open.
Fans are not working 
properly.
Close the lamp cover.
Please contact your 
Vidikron dealer for 
assistance. 
LAMP LED lights solid red.
The lamp has failed or 
exceeded its usage life.
Replace the lamp with a 
new one. 
TEMP LED lights solid red.
Vision 70 internal 
temperature is too high.
Power off the Vision 70 and 
allow it to cool down. 
Ensure that the intake and 
exhaust vents are not 
blocked. Turn the projector 
back on. If the problem 
persists, please contact 
your Vidikron dealer for 
assistance. 
Table 5-1. Troubleshooting Chart (continued)
Symptom
Possible Cause(s)
Solution