Lamp Replacement
The lamp should be replaced when it reaches the end of its life (typically 2000 hours), or 
sooner if a noticeable degradation in brightness occurs. Contact your Vidikron dealer to 
obtain a replacement lamp.
1.
Turn off the projector and unplug the power cord. 
Allow the projector to cool down for 
approximately 45 minutes prior to removing the 
lamp assembly for replacement.
2.
Loosen the three captive screws from the lamp 
cover.
 
 
3.
Remove the lamp cover. 
 
 
 
 
 
 
 
4.
Remove the two lamp assembly mounting screws.
 
 
 
 
 
 
 
5.
Grasp the lamp assembly handle and pull gently, 
removing the lamp module from the projector 
housing.
6.
Install the new lamp module and replace the two 
screws. 
 
 
 
7.
Replace the lamp cover at the right side first and 
secure it with the two screws.
8.
Turn on the power and select Lamp Hours from the 
Setup menu to reset the lamp timer (refer to Lamp 
Hours 
on page 57
). 
5