For example, a 1000-Watt lamp can be driven at no more than 1000 Watts. To produce 
desired brightness at the screen, a new lamp would likely need less than this maximum 
rating — perhaps 812 Watts (example only). Over time, however, the lamp requires more and 
more current in order to generate the desired light, until eventually the lamp wattage 
reaches its 1000-Watt maximum and the lamp power automatically levels off. At this point, 
the tracking function terminates (that is, the power level stabilizes) and the lamp begins to 
dim normally. Either reduce your “Intensity” setting or replace the lamp. 
Do not lower the “Intensity” so much that the corresponding “Power” value reaches its 
minimum — the intensity setting will be inaccurate and cannot be maintained. 
Aperture Control: The optical aperture inside the projector controls the diameter of the 
light beam passing through the system. With a fully open aperture (slidebar default of “0”), 
the maximum amount of light passes through for maximum brightness in your images. 
Increase the slidebar setting to reduce the aperture diameter and maximize contrast ratio 
instead. 
Lamp History (read-only): Lamp History shows the lamps most recently installed and 
recorded in the projector. The Lamp History automatically updates whenever you record a 
new lamp serial number; the new lamp is added to the end of the list. 
Change Lamp: Select Change Lamp from the Lamp menu to record the serial number for a 
newly-installed lamp. For detailed lamp replacement instructions, refer to Lamp and Filter 
Replacement 
on page 81. 
1. Lamps become more stable over time, thus a specific intensity is more 
easily maintained as the lamp ages.
2. Intensity can be set only if the lamp is in “Intensity” mode 
3. Intensity cannot exceed the output of Max Brightness mode.
Note