[PICTURE] menu
ENGLISH
 - 43
Settings
1)   Adjust [FULL SCAN(Y)] / [SINGLE LINE 
SCAN(Y)].
 
z
Set on [PICTURE] and use the  ▲ ▼ buttons to 
adjust [BRIGHTNESS] and then [CONTRAST].
[BRIGHTNESS]
Adjust the bottom line of the 
waveform to 0 %  
(0 or 7.5 IRE)
 
z
Setting range:  
−32 to +32
[CONTRAST]
Adjust the top line of the 
waveform to 100 %  
(100 IRE)
 
z
Setting range:  
−64 to +64
2)   Adjust [FULL SCAN(R)] / [SINGLE LINE 
SCAN(R)].
 
z
Set on [ADVANCED MENU] and use the  ▲ ▼ 
buttons to adjust [BRIGHTNESS R] and then 
[CONTRAST R].
[BRIGHTNESS R]
Adjust the bottom line of the 
waveform to 0 %  
(0 or 7.5 IRE)
 
z
Setting range:  
−16 to +16
[CONTRAST R]
Adjust the top line of the 
waveform to 100 %  
(100 IRE)
 
z
Setting range:  
−32 to +32
3)   Adjust [FULL SCAN(G)] / [SINGLE LINE 
SCAN(G)].
 
z
Set on [ADVANCED MENU] and use the  ▲ ▼ 
buttons to adjust [BRIGHTNESS G] and then 
[CONTRAST G].
[BRIGHTNESS G]
Adjust the bottom line of the 
waveform to 0 %  
(0 or 7.5 IRE)
 
z
Setting range:  
−16 to +16
[CONTRAST G]
Adjust the top line of the 
waveform to 100 %  
(100 IRE)
 
z
Setting range:  
−32 to +32
4)   Adjust [FULL SCAN(B)] / [SINGLE LINE 
SCAN(B)].
 
z
Set on [ADVANCED MENU] and use the  ▲ ▼ 
buttons to adjust [BRIGHTNESS B] and then 
[CONTRAST B].
[BRIGHTNESS B]
Adjust the bottom line of the 
waveform to 0 %  
(0 or 7.5 IRE)
 
z
Setting range:  
−16 to +16
[CONTRAST B]
Adjust the top line of the 
waveform to 100 %  
(100 IRE)
 
z
Setting range:  
−32 to +32
Note
 
z
When a 3D signal is being input (including converting 
2D to 3D), the [WAVEFORM MONITOR] cannot be 
executed.