Panasonic PT-AE8000U User Manual

Page of 110
TEMP and LAMP Indicators 
86 - ENGLISH
Maintenance
 
■ Lamp indicator <LAMP>
Indicator 
status
Illuminated red
Flashing red
Problem
Time to replace the lamp unit. Illuminates when 
the lamp unit has reached its maximum usage 
period of 3 800 hours (when [LAMP POWER] 
is set to [NORMAL]). 
Lamp circuit failure, abnormal function or lamp unit 
is damaged.
Cause
A message suggesting lamp replacement 
is displayed when power is turned on.
The power may 
have been turned on 
immediately after being 
turned off.
Lamp circuit failure, 
abnormal function or 
lamp unit is damaged.
Solution
Replace the lamp unit. 
(
 page 91)
Let the lamp unit cool 
down and turn on the 
power.
Press the <OFF> side 
of the <MAIN POWER> 
switch to turn off the 
power as described 
in the “Switching off 
the power” procedure 
(
 page 30) 
and contact 
your dealer.
Note
 
z
If the <LAMP> indicator is illuminated or flashes despite taking the actions above, please contact an Authorized Service 
Center to have your projector repaired.