Panasonic DW5100UL User Manual

Page of 72
45
When [FAILED] has appeared for an item
Parameter
MAIN CPU BUS
FAN
OPTICS MODULE
TEMPERATURE
INPUT AIR TEMPERATURE
AROUND LAMP
TEMPERATURE
LAMP REMAIN TIME
LAMP STATUS
SHUTTER
AIR FILTER
OPTICS MODULE TEMP.SENSOR
INPUT AIR TEMP.SENSOR
AROUND LAMP 
TEMP. SENSOR
BATTERY
AIRFLOW SENSOR
COLOR WHEEL
COVER OPEN
Description
Trouble has occurred in the microcomputer circuitry. Consult your dealer.
Trouble has occurred in the fan or its drive circuit. Consult your dealer.
The temperature inside the projector is high. 
It may be that the projector is being used where the ambient temperature is
high such as near a heating appliance.
The input air temperature is too high.
It may be that the projector is being used where the ambient temperature is
high such as near a heating appliance.
The temperature near the lamp has risen very high.
Something may be blocking the exhaust vent.
The lamp runtime has exceeded the prescribed cumulative time, and it is
now time to replace the lamp.
The lamp has failed to light.
Wait a short while for the lamp to cool off, and then turn on the power.
Trouble has occurred in the shutter circuitry. Consult your dealer.
Too much dust accumulates on the air filter.
Turn off the MAIN POWER switch using the procedure on page 25 and
clean the air filter (refer to page 55).
Trouble has occurred in the temperature detection sensor inside the
projector. Consult your dealer.
Trouble has occurred in the sensor used to detect the input air temperature.
Consult your dealer.
Trouble has occurred in the temperature detection sensor around lamps.
Consult your dealer.
The backup battery has been run out. Consult your dealer.
Trouble has occurred in the air volume sensor. Consult your dealer.
Trouble has occurred in the color wheel or the color wheel drive circuit.
Consult your dealer.
The lamp unit cover is not properly fitted. Check the fitting of the lamp unit
cover. (page 57)
E-mail set up page
With this projector, if a problem occurs or if the lamp usage time reaches a set value, an E-mail message can be
sent to one or more preset E-mail addresses (maximum two addresses). Click [Projector control], then [E-mail
set up] to display the E-mail set up page.
The user can enter the location of, for
example, the installed projector so that
the recipient may easily identify the
originator of the E-mail.
(maximum 63 characters)
The user can modify the threshold temperature for sending
temperature warning mail. If the temperature rises above the set
value, control sends temperature warning mail.
The user can modify the minimum time
interval of temperature warning mail.  The
default value is 60 minutes.  In this case,
the user cannot send another mail for 60
minutes after sending previous
temperature warning mail even the set
warning temperature is reached again.
Enter the IP address or server name of the
E-mail server (SMTP). The DNS server
must be set if the server name is entered.
Enter the E-mail address of the projector.
(maximum 63 characters)
Select “Enable” to use the E-mail
function.
(Continued on the next page)