Information
 Indication of monitor lamp
Five monitor lamps are provided at the top of main unit front to inform the user of the lamp replacement time and 
unusual internal temperature. These lamps indicate the degree of abnormality by combination of blinking and/or 
lighting lamps. Turn off the power and take the proper measure according to the table below.
Attention
Be sure to observe the procedure “Powering up the projector” (p. 35) and “Powering off the projector” (p. 36) 
when performing power supply operation to take a measure to the indication of temperature monitor (TEMP) lamp 
and lamp monitor (LAMP) lamp.
FILTER
CLEANING
OPEN
CLOSE
LAMP 4 monitor (LAMP 4)
LAMP 2 monitor (LAMP 2)
LAMP 1 monitor (LAMP 1)
LAMP 3 monitor (LAMP 3)
Temperature monitor (TEMP)
FILTER
CLEANING
OPEN
CLOSE
LAMP 4 monitor (LAMP 4)
LAMP 2 monitor (LAMP 2)
LAMP 1 monitor (LAMP 1)
LAMP 3 monitor (LAMP 3)
Temperature monitor (TEMP)
Name of 
monitor 
lamp
Lamp 
indication
Information
Check point
Remedial measure
TEMP 
monitor
Lighting in 
red
Warm-up status 
Did you turn on the 
power when the 
ambient temperature 
was low (approx. 0 °C)?
Wait about five minutes in the current status.
Install the unit in a location having an 
ambient temperature from 0 °C to 45 °C.

High temperature 
inside. (WARNING)
Check if the ventilation 
port is blocked.
Is the room air 
temperature too high?
Is the air filter blocked 
with dust?
Remove the object that is blocking the 
ventilation port.
Move the projector to a temperature of 0 °C 
to 45 ˚C and the humidity of 20 % to 80 % 
(no condensation).
Turn off the MAIN POWER switch using the 
procedure on page 36 and clean the air filter. 
(pp. 108-109)
Blinking in 
red
(2 times)
High temperature 
inside
(Standby condition)
Blinking in 
red
(3 times)
Cooling fan has been 
stopped.
Turn off the main power supply (MAIN 
POWER) switch in the procedure shown on 
page 36 and consult the distributor.
LAMP 
monitor
Lighting in 
red
Indicates the time for 
replacing the lamp unit.
Did you notice a 
“REPLACE THE LAMP” 
message on the screen 
when turning on the 
projector power supply?
This lamp monitor lights up when the lamp 
unit used hours have reached 1 800 hours. 
Request the dealer to replace the lamp unit.
Blinking in 
red
(3 times)
Error is detected in the 
lamp circuit.
Did you turn the power 
back on immediately 
after turning it off?
Wait until the lamp has cooled off, and then 
turn on the power.
Some error has arisen 
in the lamp circuit.
Check for fluctuation 
(or drop) in the source 
voltage.
Turn off the MAIN POWER switch using 
the procedure on page 36 and consult the 
dealer.
Name of 
monitor 
lamp
Lamp 
indication
Information
Check point
Remedial measure
TEMP 
monitor
Lighting in 
red
Warm-up status 
Did you turn on the 
power when the 
ambient temperature 
was low (approx. 0 °C)?
Wait about five minutes in the current status.
Install the unit in a location having an 
ambient temperature from 0 °C to 45 °C.

High temperature 
inside. (WARNING)
Check if the ventilation 
port is blocked.
Is the room air 
temperature too high?
Is the air filter blocked 
with dust?
Remove the object that is blocking the 
ventilation port.
Move the projector to a temperature of 0 °C 
to 45 ˚C and the humidity of 20 % to 80 % 
(no condensation).
Turn off the MAIN POWER switch using the 
procedure on page 36 and clean the air filter. 
(pp. 108-109)
Blinking in 
red
(2 times)
High temperature 
inside
(Standby condition)
Blinking in 
red
(3 times)
Cooling fan has been 
stopped.
Turn off the main power supply (MAIN 
POWER) switch in the procedure shown on 
page 36 and consult the distributor.
LAMP 
monitor
Lighting in 
red
Indicates the time for 
replacing the lamp unit.
Did you notice a 
“REPLACE THE LAMP” 
message on the screen 
when turning on the 
projector power supply?
This lamp monitor lights up when the lamp 
unit used hours have reached 1 800 hours. 
Request the dealer to replace the lamp unit.
Blinking in 
red
(3 times)
Error is detected in the 
lamp circuit.
Did you turn the power 
back on immediately 
after turning it off?
Wait until the lamp has cooled off, and then 
turn on the power.
Some error has arisen 
in the lamp circuit.
Check for fluctuation 
(or drop) in the source 
voltage.
Turn off the MAIN POWER switch using 
the procedure on page 36 and consult the 
dealer.