Panasonic WJ-FS309 User Manual

Page of 43
15
2. REC MODE
This item lets you select the time interval (field rate) for
switching the camera channel of the REC OUT signal.
When REC MODE is set to EXT, the timing is controlled by
the connected VCR. When 004-255 (INT) is selected, the
timing corresponds to the field rate set here.
The parameter settings for different VCR models are shown
in the ADDENDUM.
1. Move the cursor to the REC MODE parameter.
2. Select a field rate or EXT by pressing the 
+
or 
button.
The initial factory setting is 004 (INT).
004 - 255 (INT):
REC OUT signal is switched from one
camera channel to another at the field rate speci-
fied here.
Note:
The appropriate field rate may vary depending
on the VCR model. Consult the VCR specifications
on the field rate.
EXT:
Switching of the REC OUT signal is controlled by
the camera switching signal supplied by the con-
nected VCR.
Note:
If set to EXT, make sure that the CAMERA SW IN
terminal on the rear panel is connected to the Time
Lapse VCR.
1-1. AUTO SKIP
This item lets you enable or disable the Auto Skip function
to skip any steps where no video signal is present at the
multiscreen output.
1. Move the cursor to the AUTO SKIP parameter.
2. Select either ON or OFF.
The initial factory setting is ON.
ON:
Enables the auto skip function.
OFF:
Disables the auto skip function.
Note:
The auto skip function is not available when play-
ing back pictures.
Sequence Setup Menu
1. MULTI OUTPUT
Move the cursor to SEQUENCE SETUP on the SETUP
menu, then press the 
SET
button. The SEQUENCE SETUP
menu appears on the monitor screen as shown below.
        WJ-FS316 SETUP
        ALARM SETUP
        MONITOR OUTPUT SETUP
        REC OUTPUT SETUP 
        SEQUENCE SETUP
        SYSTEM SETUP
   
           SEQUENCE SETUP
        MULTI OUTPUT
         AUTO SKIP        ON
         SEQ MODE         QUAD
        SPOT OUTPUT
         AUTO SKIP        ON
        MLT/SPT SEQ SETUP