Panasonic WJ-FS309 User Manual

Page of 43
17
2. SPOT OUTPUT
2-1. AUTO SKIP
This item lets you enable or disable the Auto Skip function
to skip any steps where no video signal is present at the
Spot output.
Proceed as described in MULTI OUTPUT, 1.1 AUTO SKIP
on page 15.
3. MLT/SPT SEQ SETUP
This item lets you program or edit a Multi or a Spot
Sequence. Up to 9 (16) steps can be assigned in the SPOT
SEQ SETUP menu.
The duration of each step is also determined in the
MLT/SPT SEQ SETUP menu.
The initial factory setting is sequential display of 9 (16)
camera pictures.
System Setup Menu
Move the cursor to SYSTEM SETUP on the SETUP menu,
then press the 
SET
button. The SYSTEM SETUP 1/2 menu
appears on the monitor screen as shown below.
        WJ-FS316 SETUP
        ALARM SETUP
        MONITOR OUTPUT SETUP
        REC OUTPUT SETUP 
        SEQUENCE SETUP
        SYSTEM SETUP
   
             SYSTEM SETUP           1/2
        TITLE SETUP
        TITLE POSI
        CAM SW LOSS    ON
        PLAYBACK AUTO  ON
        PASSWORD       OFF
        PWR ON MULTI   QUAD-4A
        PWR ON SPOT    1   
        COM. SETUP
             SYSTEM SETUP           2/2
        ENCODE         PANA
             SYSTEM SETUP           2/2
        ENCODE         OTHERS
         SW INTERVAL   1
         NO. OF CAMS   16
  
To go to SYSTEM SETUP 2/2, press the C button.
To go back to SYSTEM SETUP 1/2, press the D button.
1. TITLE SETUP
This item lets you edit the camera title to be displayed on
the monitor screen.
Up to 8 alphanumeric characters can be displayed on the
monitor.
1. Move the cursor to TITLE SETUP parameter, then press
the 
SET
button.
The TITLE SETUP menu appears on the monitor screen
as shown on next page.
             MLT/SPT SEQ SETUP
   STEP   CH   SEC    STEP   CH   SEC
      1    1    2S       9    9    2S
      2    2    2S      10   10    2S
      3    3    2S      11   11    2S
      4    4    2S      12   12    2S
      5    5    2S      13   13    2S
      6    6    2S      14   14    2S
      7    7    2S      15   15    2S
      8    8    2S      16   16    2S
             MLT/SPT SEQ SETUP
   STEP   CH   SEC    STEP   CH   SEC
      1    1    2S       9    9    2S
      2    2    2S      10   --    0S
      3    3    2S      11   --    0S
      4    4    2S      12   --    0S
      5    5    2S      13   --    0S
      6    6    2S      14   --    0S
      7    7    2S      15   --    0S
      8    8    2S      16   --    0S
<WJ-FS316/FS416>
<WJ-FS309/FS409>
Proceed as described in MULTI OUTPUT, 1.2 SEQ MODE
on page 16.