Panasonic WJ-FS309 User Manual

Page of 43
27
ALARM/REMOTE Connector
This 25-pin connector connects alarm related control sig-
nals and/or remote switch inputs depending on the status
of pins #5 and #22. The tables below show the pin assign-
ment for the WJ-FS309/FS409 and WJ-FS316/FS416,
respectively.
13
1
25
14
For WJ-FS316/FS416
Pin #
Pin Name
For Alarm
For Remote SW1
For Remote SW2
5
Function 1
Open or +5V
GND
GND
22
Function 2
Open, +5V or 0V
Open or +5V
GND
1
Alarm/Remote 1
Alarm In 1
Remote In 1
Multiscreen
2
Alarm/Remote 2
Alarm In 2
Remote In 2
Still
3
Alarm/Remote 3
Alarm In 3
Remote In 3
Zoom
4
Alarm/Remote 4
Alarm In 4
Remote In 4
VCR/CAM
15
Alarm/Remote 5
Alarm In 5
Remote In 5
MENU
16
Alarm/Remote 6
Alarm In 6
Remote In 6
SPOT
17
Alarm/Remote 7
Alarm In 7
Remote In 7
18
Alarm/Remote 8
Alarm In 8
Remote In 8
19
Alarm/Remote 9
Alarm In 9
Remote In 9/Down
10
Alarm/Remote 10
Alarm In 10
Remote In 10/Up
11
Alarm/Remote 11
Alarm In 11
Remote In 11/Left
12
Alarm/Remote 12
Alarm In 12
Remote In 12/Right
13
Alarm/Remote 13
Alarm In 13
Remote In 13/–
23
Alarm/Remote 14
Alarm In 14
Remote In 14/+
24
Alarm/Remote 15
Alarm In 15
Remote In 15/SET
25
Alarm/Remote 16
Alarm In 16
Remote In 16/ESC
9
Alarm Output
Alarm Output
Alarm Output
Alarm Output
8
Alarm Recovery In
Alarm Recovery In
Alarm Recovery In
Alarm Recovery In
6
Alarm Reset Out
Alarm Reset Out
Alarm Reset Out
Alarm Reset Out
21
Sequence
Sequence
Sequence
7
GND
GND
GND
GND
14
GND
GND
GND
GND
20
GND
GND
GND
GND
For WJ-FS309/FS409
Pin #
Pin Name
For Alarm
For Remote SW1
For Remote SW2
5
Function 1
Open or +5V
GND
GND
22
Function 2
Open, +5V or 0V
Open or +5V
GND
1
Alarm/Remote 1
Alarm In 1
Remote In 1/Down
Multiscreen
2
Alarm/Remote 2
Alarm In 2
Remote In 2/Up
Still
3
Alarm/Remote 3
Alarm In 3
Remote In 3/Left
Zoom
4
Alarm/Remote 4
Alarm In 4
Remote In 4/Right
VCR/CAM
15
Alarm/Remote 5
Alarm In 5
Remote In 5/–
MENU
16
Alarm/Remote 6
Alarm In 6
Remote In 6/+
SPOT
17
Alarm/Remote 7
Alarm In 7
Remote In 7/SET
18
Alarm/Remote 8
Alarm In 8
Remote In 8/ESC
19
Alarm/Remote 9
Alarm In 9
Remote In 9
10
11
12
13
23
24
25
9
Alarm Out
Alarm Out
Alarm Out
Alarm Out
8
Alarm Recovery In
Alarm Recovery In
Alarm Recovery In
Alarm Recovery In
6
Alarm Reset Out
Alarm Reset Out
Alarm Reset Out
Alarm Reset Out
21
Sequence
Sequence
Sequence
7
GND
GND
GND
GND
14
GND
GND
GND
GND
20
GND
GND
GND
GND
–: No Operation
–: No Operation