Polycom DOC2702A User Manual

Page of 1010
Appendix H-Setting the MCU for Integration Into Microsoft Environment
Polycom, Inc.
H-47
In some configurations, the following flags may require modifications when 
MS_ENVIRONMENT flag is set to YES:
Setting the audio protocol for the Microsoft Client running on a single 
core PC
By default, Microsoft Office Communicator R2 or Lync Clients are connected to conferences 
using the G.722.1 audio algorithm. However, when these clients are hosted on single 
processor workstations, they may experience audio quality problems when this algorithm is 
used. 
The System Flag FORCE_AUDIO_CODEC_FOR_MS_SINGLE_CORE is used to force the 
use of a specific Audio algorithm such as G.711 when a Microsoft Office Communicator R2 or 
Lync Client is detected as being hosted on a single core processor.
This flag can be set to:
AUTO – No forcing occurs and the MCU negotiates a full set of Audio algorithm 
during capabilities exchange. 
Table H-2 
Additional Microsoft Environment Flags in the MCU MCMS_PARAMETERS_USER Tab
Flag Name
Value and Description
SIP_FREE_VIDEO_RESOURCES
Default value in Microsoft environment: NO. 
When set to NO, video resources that were allocated to 
participants remain allocated to the participants as long as 
they are connected to the conference even if the call was 
changed to audio only. The system does not allocate the 
resources to other participants ensuring that the participants 
have the appropriate resources in case they want to return to 
the video call. 
The system allocates the resources according to the 
participant’s endpoint capabilities, with a minimum of one CIF 
video resource.
When this flag is set to YES, video ports are dynamically 
allocated or released according to the in the endpoint 
capabilities. For example, when an audio Only call is 
escalated to Video and vice versa or when the resolution is 
changed.
SIP_FAST_UPDATE_INTERVAL_
ENV 
Default setting is 0 to prevent the MCU from automatically 
sending an Intra request to all SIP endpoints.
Enter n (where n is any number of seconds other than 0) to 
let the MCU automatically send an Intra request to all SIP 
endpoints every n seconds.
It is recommended to set the flag to 0 and modify the 
frequency in which the request is sent at the endpoint level 
(as defined in the next flag).
SIP_FAST_UPDATE_INTERVAL_
EP
Default setting is 0 to prevent the MCU from automatically 
sending an Intra request to Microsoft OC endpoints only, 
every 6 seconds.
Enter the number of seconds in which the MCU automatically 
sends Intra requests to Microsoft OC endpoints only.