Pelco C2900M-B(1/03 User Manual

Page of 112
C2900M-B (1/03)
73
FIRMWARE UPLOAD
Units have flash EPROMs for firmware upgrades in the field. These upgrades can be done directly
from the web browser.
Do the following to upload firmware using the web browser:
1. Obtain the latest PelcoNet NET104A Transmission System firmware from Pelco
(http://www.pelco.com).
2. Use the browser to select the General Settings configuration page of your unit.
3. Use the Browse button in the Firmware update field to select the correct new firmware file.
4. Click the Upload button.
5. After about 30 seconds you should get a feedback message from the connected unit.
6. The message “upload complete – WAIT” confirms the correct upload of the new firmware,
which is now being installed. The alarm input LEDs will flash back and forth between red and
green to indicate installation.
WARNING:  Do not disconnect power to the unit for any reason while firmware is being in-
stalled. Disrupting the cycle will damage the flash EPROM. If this occurs, you will have to return
the unit for repair.
When all the alarm input LEDs turn green, reprogramming is complete and the unit cycles
power.
7. If you try to upload an invalid firmware file, you will get the message “Upload Failed.”
8. If you revisit the General Settings configuration page after the firmware is uploaded
successfully, you will see the message “New Firmware Installed.”