Patton electronic 1195 User Manual

Page of 75
General Commands
36
Model 1195 Getting Started Guide 
5 • CLI configuration
For detailed command format, please key "? cmdname" or "help cmdname". 
See the following examples:
Command
Example
Notes
1195#? [cmdname]
{enter}
OR
1195#help [cmdname]
{enter}
 
1195#? sete1loop
 
 
<FORMAT>: sete1loop[E1ID]
 
[Local_Loop][Remote_Loop]
 
 
<EXPLAIN>: Enable/Disable 
the loopback of E1 port, 
use this command to put 
the E1 line into loop-
back mode or non-loop-
back mode
 
 
<PARAMETER>:
 
 
E1ID: <0-8>, 0: All: 1-8: 
E1ID
 
 
Local_Loop: <0/1>, loop 
status (0: non-loop ;1: 
loop)
 
 
Remote_Loop: <0/1>, loop 
status (0: non-loop ;1: 
loop)
To get further information about any 
command, type the command fol-
lowed by “?”.