Kathrein 9986492 User Manual

Page of 116
Copy Menu 
 
62
Printing the measurement results  
By pressing the softkey, the current measurement result along with the date and 
time are printed out.  
 
Printing out a measurement result in TV mode with:  
- Date and time 
- Channel number, frequency  
- Analogue measurement (A), level.  
If the function, „measure,“ is called up in the TV, Sat or FM menu, all the meas-
urements are printed out.  
Printing out all measurements in TV mode  
The printout contains the following measurement results:  
Date and time 
- Audio carrier spacing TT1: - 13 dB 
- Audio carrier spacing TT2: not available 
- Audio carrier spacing NICAM: - 20 dB 
- Bit error rate NICAM: 8.20E -06 
- Minimal level: 52.5 dBµV 
- Maximal level: 59 dBµV 
- Channel: 10 
- Video carrier frequency: 210.25 MHz 
- Analogue measurement: A 
- Current level: 56 dBµV 
 
Printing out all measurements in Sat mode  
 The printout contains the following measurement results: 
- Minimal level: 67.5 dBµV 
- Maximal level: 69 dBµV 
- Transponder frequency: 11373,15 MHz 
- Analogue measurement: A 
- Current level: 68 dBµV 
 
 
 
 
 
Line feed