DiSEqC Scope 
Calls up the last set 
menu.  
 
Increasing time / unit  
With this function, the 
DiSEqC signal can be 
compressed on the dis-
play. Eight control time-
stages are available. The unit switched 
accordingly to the next highest stage, 
when the button is pressed once more. If 
the softkey field no longer changes colour, 
the highest stage is reached.  
 
 
Reducing time / unit 
With this function, the DiSEqC signal can be stretched on the display. Eight control 
time-stages are available. The unit switches accordingly to the next lowest stage, 
once the button is pressed once more.  If the softkey field no longer changes col-
our, the lowest stage is reached.  
Saving function 
By pressing this button, the saving oscilloscope is set to standby. As soon as a 
DiSEqC signal is on the antenna socket of the MSK 33, it is recorded and saved 
until you either press the button again or switch over with the button „cont“ to con-
tinuous recording.  
Switches the oscilloscope back to continuos recording.  
 
 
Position and triggering of the DiSEqC signal  
With the cursor buttons,  ▼▲, the vertical position of the DiSEqC signal can be 
changed. The trigger point, which at 14 or 18V, is then also set or changed. 
With the horizontal cursor buttons, ◄►, the type of representation of the DiSEqC 
can be selected: 
run in seq = Swing in sequence  
run out seq = Swing out sequence  
carrier = 22 kHz carrier 
modulation = carrier modulation 
 
+ time
- time
shot
cont