IBM 8480 User Manual

Page of 64
 
Chapter 1.   Introducing the xSeries 205 Type 8480 server
 3
Features and specifications
The following table provides a summary of the features and specifications. Some 
features and specifications are not available on all models.
  
 
Microprocessor:  Supports one 
microprocessor — Intel
®
 Pentium
®
 4 
with 128 KB, 256 KB, or 512 KB 
Level-2 cache and 400 MHz or 533 
MHz front side bus (FSB)
Memory:
Minimum: 128 MB
Maximum: 2.0 GB
Type: PC2100 266 MHz double-
density RAM (DDR) DIMMs
Slots: Two dual inline 
Drives: (depending on your model) 
Diskette: 1.44 MB
Hard disk drive:  IDE or SCSI
One of the following:
— CD-ROM:  IDE
— DVD-ROM:  IDE
— CD-RW:  IDE
Expansion bays: (depending on 
your model)
Two 5.25-in. bays (one CD-
ROM drive installed)
Two 3.5-in. bays (one diskette 
drive installed)
Three 3.5-in. hard disk drive 
bays:  hot-swap drive bays 
(some models) or non-hot-swap 
drive bays with a hard disk drive 
installed (some models)
PCI expansion slots:
Three 33 MHz/32-bit on the 
system board (some models 
come with a SCSI adapter 
installed) 
Two 33 MHz/32-bit on the PCI 
extender board
Video controller:  ATI Rage XL 
video controller with 16 MB SDRAM 
video memory on the PCI extender 
card
Power supply:  One 340 watt (90-
240 V ac)
Size and weight: 
Height: 445 mm (17.5 in.)
Depth: 498 mm (19.6 in.)
Width: 165 mm (6.5 in.)
Weight:  approximately 19.5 kg (43 
lb) when fully configured or 15.9 kg 
(35 lb) minimum
 Integrated functions:
Broadcom 5702 10/100/1000 
Ethernet controller on the system 
board with RJ-45 Ethernet port
Two serial ports
One parallel port
Two  USB  ports 
Keyboard port
Mouse  port
Audio  ports
— Line  out
— Line  in
— Mic
Dual-channel bus mastering IDE 
controller
Support for IBM Remote Supervisor 
Adapter
Acoustical noise emissions:
Sound power, idling: 5.1 bel 
maximum
Sound power, operating: 5.3 bel 
maximum
Environment:
Air temperature:
— Server on: 10
°
 to 35
°
C (50.0
°
 to 
95.0
°
F). Altitude: 0 to 2133 m 
(6998.0.7 ft) 
— Server off: 10
°
 to 43
°
C (50.0
°
 to 
109.4
°
F). Maximum altitude: 
2133 m (6998.0 ft) 
Humidity:
— Computer on: 8% to 80%
— Computer off: 8% to 80%
Heat output:  Approximate heat output 
in British thermal units (Btu) per hour
Minimum configuration:  341 Btu 
(100 watts)
Maximum configuration: 1604 Btu 
(470 watts)
Electrical input:
Sine-wave input (50-60 Hz) 
required
Input voltage low range:
— Minimum: 90 V ac
— Maximum: 137 V ac 
Input voltage high range:
— Minimum: 180 V ac
— Maximum: 265 V ac
Input kilovolt-amperes (kVA) 
approximately:
— Minimum: 0.095 kVA
— Maximum: 0.470 kVA
Notes:
1.
Power consumption and heat 
output vary depending on the 
number and type of optional 
features installed and the power-
management optional features in 
use.
2.
These levels were measured in 
controlled acoustical environments 
according to the procedures 
specified by the American National 
Standards Institute (ANSI) S12.10 
and ISO 7779 and are reported in 
accordance with ISO 9296.  Actual 
sound-pressure levels in a given 
location might exceed the average 
values stated because of room 
reflections and other nearby noise 
sources.  The declared sound-
power levels indicate an upper limit, 
below which a large number of 
computers will operate.