Avaya S8100 User Manual

Page of 408
1 Install and cable a G600 cabinet
Install and wire telephones and other equipment
100
S8100 Installation and Upgrades
November 2003
Figure 23: Wiring 302C1 to a Digital Line circuit pack
Connect adjunct power
The400B2 adapter is convenient for connecting local -48 VDC power to a modular plug. See 
Figure 24: 400B2 adapter connecting to a modular plug
Adjunct power can be provided from the equipment room or equipment closet with 1145B power unit. 
The AUX connector (J1) on the Processor Interface cable can provide power for 1 attendant console.
Adjunct power can be provided locally at the telephone or console by the 1151B or 1151B2 power 
supply.
Figure notes
1
302C1 attendant console
2
4-wire Digital Line circuit pack
3
-48 VDC from adjunct power
4
Ground from adjunct power
Figure notes
1
Surface-mounted information outlet
2
To individual power unit (such as 
1151B or 1151B2)
3
400B2 adapter
4
To telephone
5
Destination service access 
point (DSAP) power cord
302cwire RPY 012098
1
39
14
40
15
2
3
6
7
8
TXT
TXR
PXT
PXR
TXT5
TXR5
PXT5
PXR5
r749428 RPY 012098