Install and cable a G600 cabinet
Connect external alarms and auxiliary connections
S8100 Installation and Upgrades
115
November 2003
Emergency transfer and auxiliary power
NOTE:
Only 1 emergency transfer power panel and 1 auxiliary power connection are provided per 
system.
Connect emergency transfer power and auxiliary power as shown in 
 on page 115. Auxiliary power includes power to an attendant console or adjunct device.
 
Telephone pin designations
 on page 115 provides pack and pin 
designations.
Table 16: Emergency transfer and auxiliary power
Power type
Color
AUX connector
Emergency Transfer
Black-Blue 
XFER48 (Pin 36)
Blue-Black
Ground (Pin 46)
Adjunct -48 VDC
Brown-Yellow
ACC48A (Pin 19)
Yellow-Brown
Ground (Pin 44)
Table 17: Port circuit pack and telephone pin designations
Pin on 
modular 
plug
4-wire; 302C1, 
8400-series, 
603E, 9403, 9434
2-wire; 302C1, 
8400-series, 603E, 
9403, 9410, 9434
8510T BRI (with 
adjunct speaker 
phone)
Analog 
station, 
modem
Z3A1 & Z3A2 
ADU, data 
module
1
TXT
TXT
2
TXR
T
TXR
3
PXT
TXT
R
PXT
4
T
PXR
5
R
PXT
6
PXR
TXR
PXR
7
-48VDC
(-48VDC)
(-48VDC)
8
GRD
GRD
GRD
circuit 
pack
4-wire digital
(8 ports)
2-wire digital
(16 or 24 ports)
4-wire BRI Trunk 
Side
Analog line 
(16 or 24 ports)
Data Line
PX
PBX transmit
T
Tip
(A)
TX
Terminal transmitR
Ring (B)