System initialization
Check system’s status
S8100 Installation and Upgrades
173
November 2003
Communication Manager alarm test
1
Access the S8100 from the SAT.
2
At the command line, type test inads.
3
Press Enter.
INTUITY alarm test
1
Access the bash from the LAC.
2
At the prompt, type logsend -tTST.
3
Press Enter.
This will result in an INTUITY AUDIX alarm that should retire within a half hour.
Windows 2000 server alarm test
1
Access the bash from the LAC.
2
At the prompt, type wrntevent GAM 0 9991.
3
Press Enter.
NOTE:
This causes a Major GAM alarm. After the system has called out, enter cleargamalarm 
all 
at the BASH prompt to retire the alarm. This alarm also causes a Maestro case to be 
generated that will need to be closed by the INADS group.
Resolve alarms
To resolve any alarms. Refer to Maintenance for Avaya S8100 Media Server with the Avaya G600 
and CMC1 Media Gateways
 (555-233-149).
Check system’s status
 on page 329 for information about bash 
commands that are used in installation and administration.
1
Open a LAC bash shell.
2
To verify system health, execute d1stat and alarmstat.
Enable customer logins