Install and cable a G600 cabinet
Install and cable a G600 cabinet
S8100 Installation and Upgrades
65
November 2003
Install and cable a G600 cabinet
!
WARNING:
Be sure there is adequate ventilation in the area. The internal room temperature must not exceed 
50
C (122
F).
A G600 cabinet can be either floor- or rack-mounted. Set the Carrier Address ID either before or after 
installing each G600.
!
WARNING:
It is very important to align the cabinet with the correct holes in the frame because the distance 
between each varies. To aid your installation of the rack-mounted cabinet, print a copy of the G600 
mounting template provided on this CD. Print the template on 11
× 17
paper, so you can use it as 
an actual template.
Verify the carrier address ID on G600 cabinets
1
Loosen the thumb screws on the fan assembly and pull it straight out as shown in 
Figure 3: Fan assembly removal
2
Verify and, if necessary, set the carrier address ID for each cabinet as shown in 
Figure 4, Setting G600 carrier address ID,
 on page 66. 
Cabinet A is the processor cabinet, and Cabinets B, C, and D are optional port carrier cabinets. 
(S8100 supports up to three cabinets, A, B, and C.)