Avaya S8100 User Manual

Page of 408
1 Install and cable a G600 cabinet
Install equipment-room hardware for G600
86
S8100 Installation and Upgrades
November 2003
1
Securely mount the external modem at the left of the modem utility shelf or another secure 
surface.
2
Route the modem cable (P2) from the Processor Interface cable to the modem and attach it to the 
modem port.
3
Plug the modem power cord into the same power source as the G600(s), preferably the UPS.
4
Connect the modem to a standard analog line using RJ45 cord.
 on page 262 describes information about modem setup, 
administration, settings, and testing.
Install equipment-room hardware for G600
See DEFINITY Communications System Generic 1 and Generic 3 Main Distribution Field Design (555-
230-630) for more information.
Cross-connect the cabinet to the patch panels
1
Cross-connect the port circuit packs to the G600 patch panels (or other standard 110A cross-
connect equipment). See 
Allowed circuit packs
 on page 86 lists the circuit packs that can be used 
with G600. (
 on page 89 lists the circuit packs that 
cannot be used with G600.)
Table 5: Allowed circuit packs and circuit modules   1 of 3
Apparatus code
Name
Allowed?
650A
AC power unit
Yes
NAA1
Fiber-Optic Cable Adapter circuit pack
Yes
TN417
Auxiliary Trunk
Yes
TN429/B/C/D
Analog Direct Inward/Outward Dialing (DIOD) Central 
Office Trunk
Yes
TN429C
Analog Central Office Trunk
Yes
TN429D
Analog DIOD Trunk – Analog Loop Start
Yes
TN433
Speech Synthesizer
Yes
TN436B
Direct Inward Dialing Trunk
Yes
TN437B
Tie Trunk Australia (future availability)
Yes
  1 of 3