Black Box ACKMODH6R User Manual

Page of 52
724-746-5500   |   blackbox.com 
Page 12
ACX1MT
724-746-5500   |   blackbox.com 
Chapter 1: Specifications
Maximum Acceptable Cable Length
Table 1-5. Maximum acceptable CATx cable length.
Cable Type
Maximum Length
Solid-conductor 24 AWG CATx cable
400 feet (140 m)
Stranded-conductor 26/28 or 27/28 AWG  or CATx cable
200 feet (70 m)
1.2.2 Fiber
A point-to-point connection is necessary. Operation with multiple patch panels is allowed. Routing over active network  
components, such as Ethernet hubs, switches, or routers, is not allowed.
Type of Interconnect Cable
(Cable notations according to VDE)
Table 1-6. Fiber cable specifications.
Cable Type
Description
Single-mode fiber 9 µm
• Duplex.
• Indoor patch cable (EFN092)
Multimode fiber 50 µm
• Duplex.
• Indoor patch cable (EFN6020)
Multimode fiber 62.5 µm
• Duplex.
• Indoor patch cable (EFN116-LCLC)
Table 1-7. Maximum acceptable fiber cable length specifications.
Cable Type
Description
Single-mode fiber 9 µm
32,800 feet (10,000 m)
Multimode fiber 50 µm (OM3)
3280 feet (1000 m)
Multimode fiber 50 µm
1300 feet (400 m)
Multimode fiber 62.5 µm
650 feet (200 m)
NOTE: If you use single-mode SFPs with multimode fibers, you can normally double the maximum acceptable cable length.