Panasonic PT-DS20KE User Manual

Page of 179
[3D SETTINGS] menu (PT-DZ21KE and PT-DS20KE only)
ENGLISH - 85
Settings
[3D PICTURE BALANCE]
Correct a shift when the brightness or color differ in 
the right eye and left eye images.
1)  Press ▲▼ to select [3D PICTURE 
BALANCE].
2)  Press the <ENTER> button.
z
The 
[3D PICTURE BALANCE] screen is 
displayed.
3)  Press ▲▼ to select an item, and press 
◀▶ to adjust the setting.
z
Correct the setting value parts of the right eye 
image based on the left eye image.
[CONTRAST] You can adjust the contrast of the 
colors.
[WHITE 
BALANCE HIGH 
RED]
Adjusts the high red white 
balance.
[WHITE 
BALANCE HIGH 
GREEN]
Adjusts the high green white 
balance.
[WHITE 
BALANCE HIGH 
BLUE]
Adjusts the high blue white 
balance.
[BRIGHTNESS] You can adjust the dark (black) 
part of the projected image.
[WHITE 
BALANCE LOW 
RED]
Adjusts the low red white balance.
[WHITE 
BALANCE LOW 
GREEN]
Adjusts the low green white 
balance.
[WHITE 
BALANCE LOW 
BLUE]
Adjusts the low blue white 
balance.
[COLOR]
You can adjust the color saturation 
of the projected image.
[TINT]
You can adjust the skin tone in the 
projected image.
[CLOCK 
PHASE]
Adjust when the screen flickers or 
outline blurs.
Note
 
z
[CLOCK PHASE] settings go are enabled at 
simultaneous input of RGB1 and RGB2 to adjust 
the right eye image.
 
z
This is disabled when [3D SYSTEM SETTING] is 
set to any setting other than [SINGLE].
 
z
This is disabled when [3D TEST PATTERN] is 
displayed.
 
z
This is disabled when [3D TEST MODE] is set to 
any setting other than [NORMAL] and [SIDE BY 
SIDE].
To display [3D WAVEFORM 
MONITOR]
The left eye and right eye images are divided and 
displayed in a waveform on the left and right.
4)  Select [3D WAVEFORM MONITOR] in 
Step 3).
5)  Press ◀▶ to switch [3D WAVEFORM 
MONITOR].
z
The setting will change as follows each time 
you press the button.
[OFF]
[ON]
[OFF]
The 3D waveform monitor is not 
displayed.
[ON]
The 3D waveform monitor is 
displayed.
Note
 
z
The 3D waveform monitor is displayed only when 
the [3D PICTURE BALANCE] screen is displayed.
 
z
The normal waveform monitor cannot be displayed 
in 3D images.
[DARK TIME SETTING]
Set the black display period to be displayed between 
the right eye image and the left eye image as 
necessary for the 3D system used.
1)  Press ▲▼ to select [DARK TIME 
SETTING].
2)  Press ◀▶ to switch [DARK TIME 
SETTING].
z
The setting will change as follows each time 
you press the button.
[0.5 ms]
[1.0 ms]
[1.5 ms]
[2.7 ms]
[2.5 ms]
[2.0 ms]
Note
 
z
This is disabled when [3D SYSTEM SETTING] is 
set to any setting other than [SINGLE].
 
z
When the setting does not correspond to the 3D 
system in use, phenomenon such as increased 
crosstalk and darkening of displayed images may 
occur.