Fostex FD-4 User Manual

Page of 100
95
MIDI Implementation Chart/MMC List/Maintenance/Specifications
MMC Command List
Command List
Movement (Recorder)
01: STOP
STOP
02: PLAY
PLAY
03: DEFERRED PLAY
DEFERRED PLAY
04: FAST FORWARD
F FWD
05: REWIND
REWIND
06: RECORD STROBE
REC
07: RECORD EXIT
PUNCH OUT
09: PAUSE
STOP
40: WRITE
Refer to MMC Response/Information Field List
41: MASKED WRITE
Refer to MMC Response/Information Field List
42: READ
Refer to MMC Response/Information Field List
44: LOCATE
LOCATE to Setting Data
47: SHUTTLE
CUE/REVIEW (+/- 1~60 times)
4C: MOVE
Refer to MMC Response/Information Field List
4D: ADD
Refer to MMC Response/Information Field List
4E: SUBTRACT
Refer to MMC Response/Information Field List
MMC Response/Information Field List
Command
01: SELECTED TIME CODE
READ/WRITE/MOVE/ADD/SUBTRACT
03: REQUESTED OFFSET
READ/WRITE
04: ACTUAL OFFSET
READ
08: GP 0
READ/WRITE/MOVE/ADD/SUBTRACT
09: GP 1
READ/WRITE/MOVE/ADD/SUBTRACT
0A: GP 2
READ/WRITE/MOVE/ADD/SUBTRACT
0B: GP 3
READ/WRITE/MOVE/ADD/SUBTRACT
0C: GP 4
READ/WRITE/MOVE/ADD/SUBTRACT
0D: GP 5
READ/WRITE/MOVE/ADD/SUBTRACT
0E: GP 6
READ/WRITE/MOVE/ADD/SUBTRACT
0F: GP 7
READ/WRITE/MOVE/ADD/SUBTRACT
48: MOTION CONTROL TALLY
READ
4C: RECORD MODE
READ/WRITE
4E: TRACK RECORD STATUS
READ
4F: TRACK RECORD READY
READ/WRITE/MASKED WRITE
51: RECORD MONITOR
READ/WRITE
Inquiry Message List
IDENTITY REQUEST: F0, 7E, <channel>, 06, 01, F7
IDENTITY REPLY: F0, 7E, <channel>, 06, 02, 51, 01, 00, 0F, 00, 01, 00, 7F, 7F, F7
51: Fostex ID
01, 00: Device family code
0F, 00: Device family number FD-4
01, 00, 7F, 7F: Software version