Kenwood TK-8180 User Manual

Page of 85
TK-8180
35
Controls
Panel Test Mode
 Test mode operation features
This transceiver has a test mode.  
To enter test mode,
press [A] key and turn power on.  Hold [A] key until fre-
quency version appears on LCD.
  Test mode can be inhib-
ited by programming.  To exit test mode, switch the power
on again.  The following functions are available in test mode.
 Key operation
Key
“FNC” not appears
Function
Display
[S]
Shifts to Panel tuning mode
-
[A]
Function on
“FNC” appears
[B]
MSK 1200bps and 2400bps
2400bps : 
 icon appears
[C]
Test signaling CH up
Signaling No.
[ ]/[ ]
Test frequency CH up/down
Channel No.
[ ]/[ ]
Volume up/down
-
[
]
Squelch on/off
[
■]
Narrow/Wide 4k/Wide 5k
Narrow : “n”,
Wide 4k : “s”,
Wide 5k : “w”
Microphone key
[PTT]
Transmit
-
[0] to [9]
Use as the DTMF keypad.
-
and [A],
If a key is pressed during
[B], [C],
transmission, the DTMF
[D], [#],
corresponding to the key
[
✳]
that was presses is sent.
Key
“FNC” appears
Function
Display
[S]
High power / Low power
Low : 
 icon appears
[A]
Function off
-
[B]
Compander on/off
On :   icon appears
[C]
Beat shift on/off
On :   icon appears
[ ]/[ ]
Function off
-
[ ]/[ ]
Function off
-
[
]
Squelch level 0
On : 
 icon appears
[
■]
LCD all lights
LCD all point appears
Microphone key
[PTT]
Transmit
-
[0] to [9] and
Function off
-
[A], [B], [C],
[D], [#], [
✳]
Notes :
• If a [S], [A], [B], [C] key is pressed during transmission, the
DTMF corresponding to the key that was pressed is sent.
• The “Wide 4k” can not use, please skip it.
• LED indicator
Red LED
Lights during transmission.
Green LED
Lights when there is carrier.
• Sub LCD indicator
“FNC”
Appears at function on.
• LCD display in panel test mode
Power
switch
Modular
MIC jack
Programmable
function keys
Volume
Up/Down key
Channel
Up/Down key
LCD
n
1
1
Channel No.
n : Narrow
s : Wide 4k
w : Wide 5k
Signaling No.
 Frequency and Signaling
The set has been adjusted for the frequencies shown in
the following table.  When required, readjust them following
the adjustment procedure to obtain the frequencies you want
in actual operation.
• Test frequency
CH
RX (MHz)
TX (MHz)
1
485.05000
485.10000
2
450.05000
450.10000
3
519.95000
519.90000
4
485.00000
485.00000
5
485.20000
485.20000
6
485.40000
485.40000
7~16
-
-
ADJUSTMENT