Kenwood TK-8180 User Manual

Page of 85
TK-8180
44
Item
Condition
Measurement
Adjustment
Specifications/Remarks
Test-
equipment
Unit
Terminal
Parts
Unit
Method
ADJUSTMENT
4. Low RSSI
1) Adj item : [n LRSSI]
SSG
Rear
ANT
After input signal
The following erroneous
adjust
Adjust : [
✳✳✳]
panel
from SSG, press [B]
performance may occur if any
• Narrow
SSG output : 12dB SINAD level AF VTVM
EXT. SP
key. That numeric
irregular RSSI adjustment,
(MOD : 1kHz/
±1.5kHz)
Oscilloscope
will be stored in
such as pressing the [B] key
memory.
assigned for determination
2) Adj item : [nL LRSSI]
 →
when it is the ANT OPEN
[nC LRSSI]
 → [nH LRSSI]
state, is performed.
Adjust : [
✳✳✳]
• The antenna bar ( ) cannot
   appear correctly.
• Wide 4k
3) Adj item : [s LRSSI]
• Scan does not stop.
Adjust : [
✳✳✳]
SSG output : 12dB SINAD level
(MOD : 1kHz/
±2.4kHz)
4) Adj item : [sL LRSSI]
 →
[sC LRSSI]
 → [sH LRSSI]
Adjust : [
✳✳✳]
• Wide 5k
5) Adj item : [w LRSSI]
Adjust : [
✳✳✳]
SSG output : 12dB SINAD level
(MOD : 1kHz/
±3.0kHz)
6) Adj item : [wL LRSSI]
 →
[wC LRSSI]
 → [wH LRSSI]
Adjust : [
✳✳✳]
5. Squelch
1) Adj item : [n SQLT]
After input signal
After adjusting SQL, check
(Tight)
Adjust : [
✳✳✳]
from SSG, press [B]
SQL open/close.
adjust
SSG output
key. That numeric
SSG 12dB SINAD level +10dB
• Narrow
: 12dB SINAD+5dB level
will be stored in
: Open
  (MOD : 1kHz/
±1.5kHz)
memory.
SSG 12dB SINAD level
: Close
2) Adj item : [nL SQLT]
 →
[nC SQLT] MOD 1kHz/
±1.5kHz
[nC SQLT]
 → [nH SQLT]
[sC SQLT] MOD 1kHz/
±2.4kHz
Adjust : [
✳✳✳]
[wC SQLT] MOD 1kHz/
±3.0kHz
• Wide 4k
3) Adj item : [s SQLT]
Adjust : [
✳✳✳]
SSG output
: 12dB SINAD+5dB level
  (MOD : 1kHz/
±2.4kHz)
4) Adj item : [sL SQLT]
 →
[sC SQLT]
 → [sH SQLT]
Adjust : [
✳✳✳]
• Wide 5k
5) Adj item : [w SQLT]
Adjust : [
✳✳✳]
SSG output
: 12dB SINAD+5dB level
  
(MOD : 1kHz/
±3.0kHz)
6) Adj item : [wL SQLT]
 →
[wC SQLT]
 → [wH SQLT]
Adjust : [
✳✳✳]