Microtek 2400 MHz Series User Manual

Page of 12
TRANSCEIVER OPERATION 
 
HOW TO SET UP EACH TRANSCEIVER 
1.  LOCATION 
Each Transceiver is designed to be placed on a flat surface for stability. The 
transceivers are not weatherproof and should be placed indoors or in an 
environmental enclosure if used outdoors or in a harsh environment. Included in 
each of MicroTek’s environmental enclosure is a piece of double-sided tape that 
can be used to mount the transceiver inside the housing. 
 
2.  POWER 
The MiniLink Data unit is powered by a 6-20 VDC power supply connected 
through the power jack at the side of the transceiver. Each transceiver 
incorporates reverse voltage protection and will draw 200 mA of power. 
 
3.  SOFTWARE CONFIGURATION 
MiniLink Data 900 or 2400 MHz Transceivers are preprogrammed at the factory 
with the following settings: 
 
Baud 4800 
Flow Control 
None 
Data Bits 
Parity None 
Stop Bits 
 
 
 
 
If your system is using the above listed protocol, there is no need to install the 
supplied MiniLink CTU Software. Identify the type of data configuration your 
system will be using and make the data connection using the RS-232 DB9 
connector or RS-485/422 4-position screw terminal. See section C “DATA 
CONNECTIONS” above for the different connection types. 
 
4.  MINILINK CTU SOFTWARE 
The MiniLink-CTU Software included with the MiniLink Data 900 or 2400 MHz 
Transceiver is provided in case it is necessary to change the parameters of the 
transceiver for a particular application. 
•  To install the MiniLink-CTU Software double-click on the 
“minilinkctu.exe” located on the media included with your transceiver. 
Follow the prompts of the installation screens. 
•  To use the MiniLink-CTU Software, connect the MiniLink Data 
transceiver from the DB9 connector on the unit to the COM1 serial port of 
a PC using the supplied straight through DB9 Serial Cable. Remember that 
the Baud Rates of the COM1 serial port and the transceiver must match, 
and 4800 is the factory setting. Also make sure that the mode select switch 
is in the RS-232 position. 
•  The MiniLink-CTU Software is organized into 3 tabs: 
i.  Set-up 
ii.  Com Test 
iii.  Configuration 
 
- 5 -