2-28
2.2.5.3 Fusing
The temperature change of the heat roller’s surface is changed to the resistance value through the 
thermistor. The Heat Roller temperate (warmup) is measured by converting the resistance of the thermistor 
to a measurable DC voltage value. The AD converter changes it to a digital value so it knows when it has 
reach its proper fusing temperature. The AC power to the fuser lamp is controller by comparing the target 
temperature to the value from the thermistor. If the value from the thermistor is out of controlling range an 
error will occur and power disabled. The table below lists the types of Fuser Errors that can occur:
•  Open Heat Error
During warmup, if the Fuser Unit does not reach its proper operating temperature within a predetermined 
time an “Open Heat Error will occur. An error message will be displayed on the Control Panel alerting the 
customer. The engine stops all functions and keeps it at the error state until the issue is resoled by a qualified 
technician.
•  Low Heat Error
After initial warmup had been achieved, if the Fuser Unit at any time does not reach its proper operating 
temperature within a predetermined time an “Low Heat Error will occur. An error message will be displayed 
on the Control Panel alerting the customer. The engine stops all functions and keeps it at the error state until 
the issue is resoled by a qualified technician.
•  Over Heat Error
If the Fuser Unit at any time exceeds the specified range [too hot] for proper operating temperature an “Over 
Heat Error will occur. An error message will be displayed on the Control Panel alerting the customer. The 
engine stops all functions and keeps it at the error state until the issue is resoled by a qualified technician.
2.2.5.4  LSU
LSU receives the image data from PVC or HPVC and makes the latent image on OPC surface.
It uses the single beam, LD. 
The errors related to LSU are as follows:
•  By LReady :  When the printing is started, the engine drives the polygon motor of LSU. After the specified 
time is elapsed, if the motor is not in a ready status, the engine detects the error that the 
polygon motor is not in a ready status. If this error happens, the engine stops all functions and 
keeps it at the error state. Also, the engine informs the error status of the main system and the 
error message is displayed at LCD window to inform the error status to the customer.
•  By Hsync :  When the polygon motor is ready, the LSU sends out the signal called Hsync and it is used to 
synchronize with each image line. So, if the engine does not detect consecutively the signal for 
a fixed time, it defines the Hsync Error. If this error happens, the engine stops all functions and 
keeps it at the error state. Also, the engine informs the error status of the main system and then 
the error message is displayed at LCD window to inform the error status to the customer. 
LSU Error Recovery: If the LReady or Hsync error occurs the paper is exited with no image on 
it. The engine mode is changed to recovery mode and the engine informs the main system of 
the engine mode. And the engine checks the LSU error. If the error doesn’t happen, the printing 
job will be proceeding.