2.7.2 
DIN Rail Mounting
The DIN Rail Mounting Kit consists of the following items:
Ø  1 x plastic moulded base
Ø  1 x plastic moulded retaining clip
Ø  1 x Metal spring
The DIN Rail Mounting Kit is supplied as an option for the inverter. If
a mounting kit is required it can be ordered using the following order
number:
Ø 6SE6400-0DR00-0AA0
In order to fit the DIN Rail Mounting Kit to the inverter, the kit
must first be assembled using the following procedure:
1.  The retaining clip is fitted into the recess of the plastic
moulded base, as shown in Drawing A.
2.  The spring is fitted into the base as shown in Drawing B.
3.  Ensure that the spring is secured to the retaining clip as shown in
Drawing B.
4.  Ensure that the retaining clip can be moved in a downward
direction, as shown in Drawing C.
When the retaining clip is released, it should return to its
normal position in an upward direction. If it does not, the
spring has been fitted incorrectly.
In order to fit the DIN Rail Mounting Kit to the inverter the following
procedure should be performed:
1.  The base is fitted to the inverter using 2 x M5 screws, as shown in
Drawing D.
2.  Ensure that the base is securely fastened to the inverter without
causing any damage to the moulded plastic base.
Ensure that the base is securely fastened to the
inverter without causing any damage to the moulded
plastic base.
1.  Clip the top recess of the base onto the DIN rail,
as shown in Drawing E.
2.  The inverter can now be pushed and locked onto the
DIN rail.
The inverter can be removed from the DIN rail by pulling
the retaining clip in a downward direction.