Intel 80C196NU User Manual

Page of 471
8XC196NP, 80C196NU USER’S MANUAL
C-38
PWMx_CONTROL
PWM
x
_CONTROL
x
 = 0–2
Address:
Reset State:
Table C-15
The PWM control (PWM
x
_CONTROL) register determines the duty cycle of the PWM 
x
 channel. A 
zero loaded into this register causes the PWM to output a low continuously (0% duty cycle).  An FFH in 
this register causes the PWM to have its maximum duty cycle (99.6% duty cycle).
7
0
PWM Duty Cycle
Bit 
Number
Function
7:0
PWM Duty Cycle
This register controls the PWM duty cycle.  A zero loaded into this register causes the 
PWM to output a low continuously (0% duty cycle).  An FFH in this register causes the 
PWM to have its maximum duty cycle (99.6% duty cycle).
Table C-15.  PWM
x_CONTROL Addresses and Reset Values
Register
Address
Reset Value
PWM0_CONTROL
1FB0H
00H
PWM1_CONTROL
1FB2H
00H
PWM2_CONTROL
1FB4H
00H