Black Box 422 User Manual

Page of 28
Page 16
724-746-5500   |   blackbox.com
 
Chapter 3: Installation and Configuration
3.4.4 Echo
The RS-485 “Echo” is the result of connecting the receiver inputs to the  
transmitter outputs. Each time a character is transmitted, it is also received.  
This can be beneficial if the software can handle echoing (that is, using received 
characters to throttle the transmitter), but it can also confuse the system if the 
software cannot support echoing. 
Echo configuration is software selectable for half-duplex RS-485. By default, 
ECHO is disabled, and this configuration can be set by placing a check next to 
“Enable Echo” in the “RS-485 Advanced Configuration” field, as shown in Figure 
3-4.
Figure 3-4. Enable Echo.
3.4.5 Status LEDs
Status LEDs on the front of the converter indicate the following information: 
• MODE (Red or Green) – Indicates the electrical interface selected  
   - Green indicates RS-232 mode  
   - Red indicates RS-422 or RS-485 mode 
• DATA (Green) – Blinks to indicate data is being transmitted or received