User ManualTable of Contents3Com® Switch 8800 FamilyInstallation Guide1Contents3About This Guide5Conventions5Related Documentation6About this Document6Product Overview7Preface7General Architecture10Chassis and Slots10Switch 880710Switch 881011Switch 881412Backplane12Functions12Structure12AC Power System13PoE Power Supply13PoE entry area14External PoE Power Rack (3C17509)14MBUS15Introduction15Role and function16Fan Tray16Fabric Modules17360 Gbps Switch Fabric17Technical specifications17Panel17Compact Flash (CF slot)18Management Ports18RESET button19Status LEDs19720 Gbps Switch Fabric21Technical specifications21Panel21Compact Flash (CF slot)21Management Ports21RESET button23Status LEDs23RESET button24Status LEDs24System Specifications24Software Features25I/O and Application Modules29Overview293C17511 1-port 10GBASE-X (XENPAK)29Specifications29Panel and LEDs30Matching Cable303C17512 2-port 10GBASE-X (XFP) Module30Specifications30Panel and LEDs31Matching Cable313C17513 12-port 1000BASE-X (SFP) Module31Specifications31Panel and LEDs31Matching Cable323C17514 24-port 1000BASE-X (SFP) Module32Specifications32Panel and LEDs32Matching Cable333C17516 24-port 10/100/1000BASE-T Module33Specifications33Panel and LEDs333C17525 1-port 10GBASE-X Advanced (XENPAK) Module33Specifications33Panel and LEDs34Matching Cable343C17526 4-port 10GBASE-X (XFP) Module34Specifications34Panel and LEDs35Matching Cable353C17527 2-port 10GBASE-X (XFP) Advanced Module35Specifications35Panel and LEDs35Matching Cable363C17528 48port 10/100/1000 BASE-T (RJ-45) Module36Specifications36Panel and LEDs363C17530 24-port 1000BASE-X (SFP) Advanced Module37Specifications37Panel and LEDs37Matching Cable373C17531 24-port 10/100/1000BASE-T Advanced Module37Specifications37Panel and LEDs383C17532 48-port 10/100/1000 BASE-T (RJ-45) Access Module38Specifications38Panel and LEDs393C17533 24-port 1000BASE-X (SFP) IPv6 Module39Specifications39Panel and LEDs39Matching Cable403C17534 24-port 10/100/1000BASE-T IPv6 Module40Specifications40Panel and LEDs403C17536 4-port 10GBASE-X (XFP) QUAD IPv6 Module40Specifications40Panel and LEDs41Matching Cable413C17537 2-port 10GBASE-X (XFP) IPv6 Module41Specifications41Panel and LEDs42Matching Cable423C17538 48-port 1000BASE-X (SFP) IPv6 Module42Specifications42Panel and LEDs42Matching Cable43Application Modules433C17542 Network Monitoring Application Module43Technical specifications43Front panel433C17546 Firewall Application Module44Technical specifications44Front panel44Available cables443CR1754766 IPsec Module44Technical specifications44Front panel45Available cables453C17548 VPLS Application Module45Technical specifications45Front panel46Transceivers46Switch 8800 Port Densities47Installation Preparation49Safety Recommendations49General Safety Recommendations49Safety Recommendations against Electricity49Safety Recommendations in Moving the Switch 8800 Family49Wearing an ESD-Preventive Wrist Strap50Safety Recommendations against Laser50Examining Installation Site50Temperature/Humidity Requirements50Cleanness Requirements51Anti-Static Requirements51Grounding Requirements51Power Supply Requirements52Space Requirements52Cabinet-Mounting Requirements52Installation Tools52Switch Installation53Confirming Installation Preparation53Installation Flow53Mounting the Switch in User-Supplied Cabinet54Cabinet Configuration Guideline54One Switch 8807 chassis in a cabinet54Two Switch 8807 chassis in a cabinet55One Switch 8810 chassis in a cabinet56One Switch 8814 chassis in a cabinet57Mounting the Switch in the Cabinet58Connecting PGND Wire and Power Cord59Connecting PGND Wire59Common grounding environment59Other grounding environment59Connecting AC Power Cord61Connecting PoE Power Cord63Grounding PoE chassis63Connecting PoE power cable63Installing Cabling Rack64Installing Fan Tray64Installing PoE Lightning Protection Box65Installing I/O modules66Connecting Interface Cables67Connecting Console Cable67Introduction67Connecting console cable67Connecting AUX Cable68Introduction68Connecting AUX cable69Connecting Category-5 Shielded Cable69Introduction to RJ-45 connector69Connecting category-5 shielded cable69Connecting Fiber69Introduction to fiber connector69Connecting fiber70Cable Routing Recommendations70Freestanding Switch on Tabletop70Cabinet-Mounting Switch70Cable Management70Cable Management Requirements70Verifying the Installation73Debugging the System75Setting up Configuration Environment75Connecting the Cables75Setting the Terminal Parameters75Powering and Booting the Switch76Verifying Installation before Powering the Switch76Powering on the Switch76Verifying after Power-on (Recommended)76Boot Interface77Switch Monitoring and Maintenance79Monitoring the Switch79Troubleshooting Console Terminal79Troubleshooting the PSU79Display Power Command Indicates the PSU is Not in Position80The Input LED (green) and Output LED (green) are OFF80The Fail LED (red) is ON80Troubleshooting Fan Tray80Troubleshooting I/O Module81Hardware Maintenance81Replacing AC PSU81Removing an AC PSU81Installing an AC PSU82Replacing and Cleaning the PCU’s Air Filter82Removing and cleaning the air filter of PSU82Installing the air filter of PSU83Replacing and Cleaning the Chassis’s Air Filter83Removing and Cleaning the Chassis’s Air Filter84Installing the Chassis’s Air Filter84Replacing a Module84Required tools84Removing a Module84Installing a Module85Replacing the Fan Tray85Required tools85Replacing the Fan Tray85Upgrading the Software86Required cables86Upgrading Locally through the Boot Menu86Upgrading software through console port (XModem)88Upgrading the Software Using TFTP90Upgrading software Using (FTP)92Upgrading the Software Using the CLI93Using FTP93Using TFTP94Upgrading the Application Module Program94Troubleshooting the Software Upgrade94No response from the fabric serial interface94Uploading the configuration file or host program using FTP fails94The configuration did not save during the I/O module reboot94I/O module program loading fails or you cannot register for a long period94Insufficient Flash memory95Password Loss95Lightning Protection of the Switch97Installing a Lightning Arrester for the AC Power97Installing a Lightning Arrester for the Network Port98Required tools98Installation procedure98Installation precautions993Com Network Management1013Com Network Supervisor1013Com Network Director1023Com Network Access Manager1023Com Enterprise Management Suite103Integration Kit with HP OpenView Network Node Manager103Size: 3.16 MBPages: 104Language: EnglishOpen manual
User ManualTable of ContentsAbout This Guide5Conventions5Related Documentation6Product Overview7Preface7General Architecture10Chassis and Slots10Backplane12AC Power System13PoE Power Supply13MBUS15Fan Tray16Fabric Modules17360 Gbps Switch Fabric17720 Gbps Switch Fabric21System Specifications24Software Features25I/O and Application Modules29Overview293C17511 1-port 10GBASE-X (XENPAK)29Specifications29Panel and LEDs30Matching Cable303C17512 2-port 10GBASE-X (XFP) Module30Specifications30Panel and LEDs31Matching Cable313C17513 12-port 1000BASE-X (SFP) Module31Specifications31Panel and LEDs31Matching Cable323C17514 24-port 1000BASE-X (SFP) Module32Specifications32Panel and LEDs32Matching Cable323C17516 24-port 10/100/1000BASE-T Module33Specifications33Panel and LEDs333C17525 1-port 10GBASE-X Advanced (XENPAK) Module33Specifications33Panel and LEDs34Matching Cable343C17526 4-port 10GBASE-X (XFP) Module34Specifications34Panel and LEDs35Matching Cable353C17527 2-port 10GBASE-X (XFP) Advanced Module35Specifications35Panel and LEDs35Matching Cable363C17528 48port 10/100/1000 BASE-T (RJ-45) Module36Specifications36Panel and LEDs363C17530 24-port 1000BASE-X (SFP) Advanced Module37Specifications37Panel and LEDs37Matching Cable373C17531 24-port 10/100/1000BASE-T Advanced Module37Specifications37Panel and LEDs383C17532 48-port 10/100/1000 BASE-T (RJ-45) Access Module38Specifications38Panel and LEDs393C17533 24-port 1000BASE-X (SFP) IPv6 Module39Specifications39Panel and LEDs39Matching Cable403C17534 24-port 10/100/1000BASE-T IPv6 Module40Specifications40Panel and LEDs403C17536 4-port 10GBASE-X (XFP) QUAD IPv6 Module40Specifications40Panel and LEDs41Matching Cable413C17538 48-port 1000BASE-X (SFP) IPv6 Module41Specifications41Panel and LEDs42Matching Cable42Application Modules423C17542 Network Monitoring Application Module423C17546 Firewall Application Module433CR1754766 IPsec Module433C17548 VPLS Application Module44Transceivers45Switch 8800 Port Densities46Installation Preparation47Safety Recommendations47General Safety Recommendations47Safety Recommendations against Electricity47Safety Recommendations in Moving the Switch 8800 Family47Wearing an ESD-Preventive Wrist Strap48Safety Recommendations against Laser48Examining Installation Site48Temperature/Humidity Requirements48Cleanness Requirements49Anti-Static Requirements49Grounding Requirements49Power Supply Requirements50Space Requirements50Cabinet-Mounting Requirements50Installation Tools50Switch Installation51Confirming Installation Preparation51Installation Flow51Mounting the Switch in User-Supplied Cabinet52Cabinet Configuration Guideline52Mounting the Switch in the Cabinet56Connecting PGND Wire and Power Cord57Connecting PGND Wire57Connecting AC Power Cord59Connecting PoE Power Cord61Installing Cabling Rack62Installing Fan Tray62Installing PoE Lightning Protection Box63Installing I/O modules64Connecting Interface Cables65Connecting Console Cable65Connecting AUX Cable66Connecting Category-5 Shielded Cable67Connecting Fiber67Cable Routing Recommendations68Freestanding Switch on Tabletop68Cabinet-Mounting Switch68Cable Management68Cable Management Requirements68Verifying the Installation71System Debugging73Setting up Configuration Environment73Setting up Configuration Environment73Connecting Cables73Setting Terminal Parameters73Powering and Booting the Switch74Verifying Installation before Powering the Switch74Powering on the Switch74Verifying after Power-on (Recommended)75Boot Interface75Switch Monitoring and Maintenance77Monitoring the Switch77Troubleshooting Console Terminal77Troubleshooting PSU77Troubleshooting Fan Tray78Troubleshooting I/O Module78Hardware Maintenance79Replacing AC PSU79Replacing and Cleaning the Air Filter of PSU80Replacing and Cleaning the Air Filter of Chassis82Replacing a Module82Replacing the Fan Tray83Software Upgrade84Upgrade preparations84Local Loading through Boot Menu85Local or Remote Loading through CLI91Application Module Program Upgrade92Troubleshooting Software Upgrade93Password Loss93Lightning Protection of the Switch95Installation of Lightning Arrester for AC Power (Socket Strip with Lightning Protection)95Installation of Lightning Arrester for Network Port96Size: 3.11 MBPages: 97Language: EnglishOpen manual