User ManualTable of ContentsTable of Contents3About This Book15This Book’s Organization15Other Books16Trademarks171. Overview and Roadmap19System Reliability19Standard Reliability20High Reliability20Critical Reliability20DEFINITY System Installation Roadmap21Plan and Prepare the Site21Unpack the Cabinets21Install and Connect the Cabinets21Install Telecommunications Cabling22Install Generic 3 Management Terminal (G3-MT)22Activate the System23Test the System23Install and Wire Telephones and Other Equipment24Administer the DEFINITY System According to Custom...25Test Telephones and Other Equipment252. Plan and Prepare the Site27Check the Customer’s Order27Locate and Lay Out the Equipment Room28Generic 3 Management Terminal (G3-MT) Requirements...28Cross-Connect Fields28Space Requirements28Room Layout28Additional Notes:29Cable Slack Manager (Optional) Requirements30Tools Needed30Lay Out and Ensure Appropriate Power32Power Arrangements for AC Power32Power Arrangements for DC Power33Lay Out and Ensure Appropriate Grounding34Connect Coupled Bonding Conductor34Determine the Location of the Equipment Closets35Determine External Trunk Locations35Create a Provisioning Plan353. Unpack the Cabinet37Unpack and Inspect for Damage37Figure Notes:38Figure Notes:394. Install and Connect the Cabinets41Install Earthquake Mounting42Position and Stack the Cabinets42Connect System Cabinet Grounds43Connect Battery Leads45Figure Notes:45Connect Power46Connect AC Power46Connect DC Power46Connect Power Plant Ground49Connect Frame Ground50Connect DC Power Distribution Box Grounding51Connect Single-Carrier Network Grounding51Coupled Bonding Conductor (CBC)52Connect DC Power to Networks54Connect AC Power to DC Power Cabinet54Test DC Power Plant54Connect Stand-by Power54Locate and Connect Time Division Multiplexing (TDM...55Locate and Connect Inter-Cabinet Cables (ICC)57Install Fibre-Optic Cables59Fibre-Optic Cable Operation59Locate Fibre-Optic Cable Connections59General Rules and Recommendations for Connecting F...60Rule 160Rule 260Rule 361Rule 461Rule 561Recommendation61Raised Floor or Cable Slack Managers63Figure Notes:64Cable Connections64Standard Reliability Fibre-Optic Cable Connections...65High Reliability Fibre-Optic Cable Connections66Critical Reliability Fibre-Optic Cable Connections...67Verify Port Cabinet Address Plugs69Figure Notes:69Install Back Panels70Install Ground Plates70Figure Notes:70Install Ground Plates on Systems with Earthquake P...71Install Ground Plates on Systems without Earthquak...71Figure Notes:73Install Cable Clamps74Figure Notes:74Install Front Plates75Install Front Plates on Systems with Earthquake Pr...75Install Cabinet Clip On Systems without Earthquake...755. Install Telecommunications Cabling77Install the Cross-Connect Field77Typical Cross-Connect Field Using 110-Type Hardwar...77Hardware Installation79Install Cable Slack Managers79Route Cables from Cabinet to Cross- Connect Field79Connect Control Carrier Outputs Cable82Label Cables83Install Trunk Cables Among Network Interface, Snea...836. Install Generic 3 Management Terminal85Generic 3 Management Terminal (G3-MT) Requirements...85Figure Notes:86Connect Generic 3 Management Terminal (G3-MT)86Set Up G3 Management Terminal (G3-MT)90Remotely Connect Generic 3 Management Terminal (G3...917. Activate the System93Power Up Switch94Install Translation Flash-Memory Card94Figure Notes:94Power up AC-Powered Switch95Power up DC-Powered Switch95Verify Messages on Terminal95Introduction to Terminal Screens and Commands96Screens96Commands97Getting Help97Log in to the System97Set Required Country Options98Change Craft Password101Set Date and Time103Set System Maintenance Parameters106Save Translations107Logoff1098. Test the System111Check the System Status for Each Cabinet111Check Circuit Pack Configuration114Test Time Division Multiplexor (TDM) Bus in Proces...119Test Tone-Clock Boards120Test Switch Processing Element (SPE) Duplication M...121Test Duplicated Switch Processing Element (SPE) In...122Test Expansion Interface Boards124Test Time Division Multiplexer (TDM) for each Expa...125Test Tone-Clock for each Expansion Port Network (E...126Test Tone-Clock Interchange for each Expansion Por...127Test Expansion Interface Exchange for Each Expansi...127Check Circuit Pack Configuration Again129Save Translations, if Required130Re-install Front Doors130Next Steps1309. Install and Wire Telephones and Other Equipment131Telephone Connection Example131Figure Notes:133Connect Adjunct Power133Figure Notes:134Analog Station or 2-Wire Digital Station Example135Figure Notes:136Analog Tie Trunk Example136Figure Notes:138Digital Tie Trunk Example139Figure Notes:140Auxiliary Connector Outputs140Figure Notes:145APP Connector and Cable Diagrams (Pinout Charts)145Install Initialization and Administration System (...151Install Emergency Transfer Units and Associated Te...153Install the 808A Emergency Transfer Panel153Install External Ringing154Requirements154Installation154Install Queue Warning Indicator155Requirements155Installation156Install the 1145B1 Power Supply156Wall-Mounting Plates157Mount the 1145B1 Power Supply159Mount the 1146B1 Power Distribution Unit160Battery Mounting/Wiring160Power Up and Test161Wire the 1146B1 Power Distribution Unit162Reset Light Emitting Diodes (LED) on Power Distrib...163Install the MSP-1 Power Supply164Underwriter’s Laboratories (UL) Information164Important Safety Instructions165Description of the MSP-1 Power Supply166Locate the MSP-1 Power Supply166Mount the MSP-1 Power Supply166Connect the Power Supply167Install the Basic Rate Interface (BRI) Terminating...169Terminating Resistor Adapter170Closet Mounted (110RA1-12)171Install Multipoint Adapters173BR851-B Adapter (T-Adapter)173Figure Notes:174367A Adapter174Figure Notes:175Basic Multipoint Installation Distances175Install Power Adapters177400B2177Figure Notes:178400F2178Figure Notes:179Install Auxiliary Equipment179Auxiliary Equipment Description179Install Loudspeaker Paging and Music-on-Hold180Install Loudspeaker Paging Access without Paging A...180Requirements180Install Loudspeaker Paging Access181Install Music-on-Hold Access182Requirements182Install Federal Communications Commission (FCC) Re...184Install Recorded Announcement Equipment184Requirements184Install Processor Data Modules (PDMs)185Requirements185Installation186Connection to Data Mounting186Connection to Individual Processor Data Modules (P...187Install Call Management System (CMS) Interface188Install Property Management System (PMS) Interface...189Requirements189Install Customer-Provided Terminal Using Asynchron...191Requirements191Installation191Install Station Message Detail Recording (SMDR)/Ca...192Interface Cabling to Station Message Detail Record...193Figure Notes:195Switch Settings for Processor Data Module (PDM), T...195212-Type Modem Switch Setting196Implement and Administer System Data19610. Test Telephones and Other Equipment197Make Test Calls (Single-Cabinet Switch)198Description198Procedure198Make Test Calls (Two-Cabinet Switch)199Description199Procedure199Make Test Calls (Three-Cabinet Switch)200Description200Procedure201Test the Attendant Console204Description204Procedure204Test the Selector Console205Description205Procedure205Test External Ringing205Description205Procedure—Ringing Device Installed205Procedure—Ringing Device Not Installed206Test Queue Warning Indicator206Description206Procedure—Queue Warning Indicator Installed206Procedure—Queue Warning Indicator Not Installed207Test Integrated Announcement208Description208Procedure — Record Announcement208Procedure — Playback Announcement208Procedure —Delete Announcement208Test Music-on-Hold209Description209Procedure209Test Emergency Transfer209Description209Procedure210Test Remote Access Interface (known as Initializat...210Description210Procedure—Remote Test210Procedure—Local Test211Test Basic Rate Interface (BRI)211Description211Procedure—Dial Tone211Procedure—Make and Receive Calls211Procedure—Checking the Service Profile Identifier ...212A. Approved Grounds213Definition of Approved Ground213Acceptable Mediums for Protective Ground213Approved Floor Grounds214B. Earthquake Protection Procedures215Install Floor Mounting to Attach Cabinet to Floor215Figure Notes:217Install Ground Plates on Cabinet Backs218Install Front Plates218Figure Notes:219C. DEFINITY AUDIX System Power Procedures221Manually Power Down DEFINITY AUDIX System221Figure Notes:223Manual Power Up DEFINITY AUDIX System223D. Country Differences225United States to United Kingdom and France Termino...225Country-Specific Hardware225E. Installing the 9400-Series Telephones245Installing the 9400-Series Telephones245Wiring Information246Distance Limitations248Wall Mounting250Figure Notes:250Figure Notes:251Figure Notes:252Using the Test Feature253The Test Feature253Button Labels254F. Wire Conversion Information255Common Wire Colours255AWG to SWG Conversion (Stranded Wire)255Wire Gauge Comparison (Solid Conductor)258G. Electrical Code Equivalencies263North American Electrical Code263International Electrical Codes263H. Option Switch Settings265Distributed Communications System (DCS) Option Set...265Modem Pooling (Combined) Option Settings266103JR Modem Option Settings266201CR Modem Option Settings268202SR Modem Option Settings270208BR Modem Option Settings273Asynchronous 212AR Modem Option Settings275Synchronous 212AR Modem Option Settings278Asynchronous 2224A Modem Option Settings281Synchronous 2224A Modem Option Settings2827400A Option Settings283Printer Option Settings284475 Printer Connected to a G3 Management Terminal285475 Printer Used as System Printer285475 or 476 Printer Used as Journal Printer for Hos...285470 or 471 Printer Used as Journal Printer for Hos...292572 Printer294Station Message Detail Recording (SMDR) Interface ...299Audio Information Exchange (AUDIX) Interface Optio...301TN760 Tie Trunk Circuit Pack Option Settings301TN464C, D, E, F Option Settings305TN464C/D Option Settings305TN464E/F Option Settings306I. References309Basic309Call Center313Networks314Application Specific315Abbreviations319Index323Size: 2.67 MBPages: 332Language: EnglishOpen manual