User ManualTable of ContentsRosemount 4500 Hygienic Pressure Transmitter for Life Sciences Applications1Table of Contents5SECTION 1 Introduction5SECTION 2 Installation5SECTION 3 Configuration5SECTION 4 Operation and Maintenance6SECTION 5 Troubleshooting6APPENDIX A Reference Data6APPENDIX B Product Certificates6Section 1 Introduction7Using This Manual7Service Support8Section 2 Installation9Overview9Safety Messages9Warnings9Considerations10General10Environmental10Installation Procedures12Electronics Housing12Cover Installation12Mount the Transmitter12Set Switches13Security (Write Protect)13To reposition the switches, follow the procedure described below.13HART Communicator14AMS14Configure Alarm Direction14HART Communicator14AMS14Connect Wiring and Power Up15Wiring for HART Protocol15Signal Wiring Grounding15Power Supply 4-20 mA Transmitters15Grounding16Transmitter Case16Installing the LCD Meter16Ambient16Storage16Section 3 Configuration17Overview17Safety Messages17Warnings17Commissioning on the bench With HART18Setting the Loop to Manual18Wiring Diagrams19Bench Hook-up19Field Hook-up19HART Communicator20Menu Tree20Fast Key Sequence21Review Configuration Data22HART Communicator22AMS22Check Output23Process Variables23HART Communicator23AMS23Sensor Temperature23HART Communicator23AMS23Basic Setup24Set Process Variable Units24HART Communicator24AMS24Rerange24Rerange with a HART Communicator Only25Rerange with a Pressure Input Source and HART Communicator25Rerange with a Pressure Input Source and the Local Zero and Span buttons (option D1)25Rerange with AMS only26Rerange with a Pressure Input Source and AMS26Damping26AMS26LCD Display26LCD Display Configuration27AMS27Detailed Setup27Failure Mode Alarm and Saturation27Alarm and Saturation Level Configuration28HART Communicator28AMS29Alarm and Saturation Levels for Burst Mode29Alarm and Saturation Values for Multidrop Mode29Alarm Level Verification30Process Alerts30HART Communicator30AMS30Scaled Variable Configuration31HART Communicator32AMS33Re-mapping33HART Communicator33AMS34Right click on the device and select “Device Configuration,” then “Re-mapping” from the menu.34Sensor Temperature Unit34AMS34Diagnostics and Service34Transmitter Test34AMS34Loop Test35HART Communicator35AMS36Advanced Functions for HART Protocol36Saving, Recalling, and Cloning Configuration Data36HART Communicator36AMS creating a Reusable Copy37AMS Applying a User Configuration38Burst Mode38HART Communicator38AMS39Multidrop Communication39Changing a Transmitter Address40HART Communicator40AMS40Communicating with a Multidropped Transmitter40HART Communicator40AMS40Polling a Multidropped Transmitter40HART Communicator40AMS40Section 4 Operation and Maintenance41Overview41Calibration for HART Protocol41Calibration Overview42Configure the output parameters42Calibrate the sensor42Calibrate the 4-20 mA output42Determining Calibration Frequency44Choosing a Trim Procedure45Sensor Trim45Zero Trim46HART Communicator46AMS46Full Trim46HART Communicator46AMS47Recall Factory Trim47Recall Factory Trim- Sensor Trim47AMS47Recall Factory Trim- Analog Output48AMS48Analog Output Trim48Digital-to-Analog Trim48HART Communicator48AMS49Digital-to-Analog Trim Using Other Scale49AMS49Diagnostic Messages50Error Indicator50Fail Module50Fail Config50Warnings50PV Limit50NonPV Limit51Curr Sat51Loop Test51Xmtr Info51PRESS ALERT51Temp Alert51Operation51Zero Pass51Zero Fail51Span Pass51Span Fail52Keys disabl52Stuck Key52Section 5 Troubleshooting53Overview53Safety Messages53Warnings53Specifications55Performance Specifications55Functional Specifications56Physical Specifications58Dimensional Drawings59Ordering Information62Approved Manufacturing Locations63Ordinary Locations Certifications63European Directive Information63Hazardous Locations Certifications64North American Certifications64Canadian Standards Association (CSA) Approvals (Pending)64Index67A67B67C67D67E67F67G67I67L67M67N67O67P68R68S68T68U68W68Z68Size: 1.92 MBPages: 70Language: EnglishOpen manual