User ManualTable of ContentsFront Page1Notices3Contents5Section 1 Introduction111.1 Safety messages111.2 Manual overview121.3 Service and product support121.4 Product recycling/disposal12Section 2 Transmitter Overview132.1 Introduction to the transmitters132.2 Theory of operation132.3 Components of the transmitter142.4 System architecture14Section 3 Installation173.1 Safety messages173.2 Considerations before installation183.2.1 Safety considerations183.3 Mechanical installation193.3.1 Consider the liquid surface conditions203.3.2 In-tank effects203.3.3 Mounting the transmitter above the liquid surface213.3.4 Open channel flow installations233.4 Electrical installation263.4.1 Connecting the cable(s) to the transmitter263.4.2 Connecting the cable wires to the MSP400RH273.4.3 Connecting the cable wires to the MSP900GH283.4.4 Remote temperature sensor293.4.5 Wiring to allow HART communications293.4.6 Lightning / Surge protection and other loop devices30Section 4 Starting up314.1 Overview314.1.1 Display and push-buttons314.1.2 Power up324.1.3 Before programming334.2 Programming334.2.1 Overview334.2.2 Selecting the duty344.2.3 Selecting the units of measurement354.2.4 Setting the correct bottom reference364.2.5 Selecting a profile374.2.6 Power Factor for the Flow Law414.2.7 K-factor for the flow law424.2.8 Maximum level entry434.2.9 Maximum flow entry444.2.10 Maximum contents (volume) entry454.2.11 Setting the 4 mA point464.2.12 Setting the 20 mA point474.2.13 Setting the output damping484.2.14 Selecting the alarm condition action494.2.15 Setting the relay on and off points (MSP400RH)504.2.16 Setting the 4 and 20 mA levels using ranging514.3 Final checks534.4 Power failure53Section 5 Service and Troubleshooting555.1 Safety messages555.2 Servicing565.3 Diagnostics565.3.1 General troubleshooting565.3.2 Diagnostic data565.3.3 Loop test575.4 Engineering menu595.4.1 Accessing the engineering menu595.4.2 Setting the threshold595.4.3 Setting lost echo time605.4.4 Setting the dead band615.4.5 Setting the frequency625.4.6 Setting the pulse repetition frequency635.4.7 Setting valid echo count645.4.8 Setting Spike Rejection655.4.9 Learn about echoes from false targets665.4.10 Setting the ambient temperature675.4.11 Temperature calibration685.4.12 Loading factory default values695.4.13 Changing the base units705.5 False echoes under certain ambient operating conditions72Appendix A Reference Data73A.1 Specifications73A.1.1 General73A.1.2 Measuring performance73A.1.3 Display and configuration73A.1.4 Electrical74A.1.5 Physical specifications75A.1.6 Mechanical75A.1.7 Measuring75A.1.8 Environment76A.2 Dimension drawings78Appendix B Product Certifications81B.1 Safety messages81B.2 Approved manufacturing location81B.3 European directive information82B.4 Ordinary locations certification (MSP400RH only)82B.5 Hazardous locations certifications (MSP900GH only)82Appendix C Integrated Display Menus85C.1 Main menu map86C.2 Diagnostics menu map88C.3 Engineering menu map89Appendix D Mobrey MCU900 Series91D.1 Introduction91Appendix E Field Communicator95E.1 Introduction95E.2 Safety messages95Appendix F Configuring Using HART99F.1 Overview99F.2 Command parameters100F.2.1 Base units100F.2.2 Set as empty101F.2.3 Present depth102F.2.4 Learn false echo103F.2.5 Auto tank map104F.2.6 Simulation of PV105F.2.7 Restart device106F.2.8 Load defaults107F.2.9 Simulate current output108F.2.10 Trim 4 mA / Trim 20 mA109F.3 Configuration parameters111F.3.1 Message (P000)111F.3.2 Tag (P001)112F.3.3 Descriptor (P002)112F.3.4 Final assembly number (P004)113F.3.5 Serial number (P005)114F.3.6 Bottom reference (P010)115F.3.7 Upper blanking (P023)117F.3.8 Lower blanking (P063)118F.3.9 Distance offset (P060)119F.3.10 Level offset (P069)120F.3.11 Tank shape / non-linear profile (P011)121F.3.12 Contents (volume) measurement122F.3.13 Flow measurement126F.3.14 Primary variable units (P012)130F.3.15 Scale Factor / K-Factor (P013)131F.3.16 Profile height / Power factor (P014)132F.3.17 Profile points 1 to 10 (P030 to P039)134F.3.18 Upper range value (P015)135F.3.19 Lower range value (P016)136F.3.20 Damping (P020)137F.3.21 Setting-up relays on the MSP400RH138F.3.22 Relay 1 (P070 to P072)138F.3.23 Relay 2 (P073 to P075)138F.3.24 Lost echo delay (P021)138F.3.25 Lost echo action (P022)140F.3.26 Speed of sound (P024)141F.3.27 Temperature (P025)142F.3.28 Set threshold (P026)143F.3.29 Transmit power control (P040)145F.3.30 Pulse repeat (P041)146F.3.31 Echoes needed (P042)146F.3.32 Threshold 1 time (P043)147F.3.33 Threshold 1 size (P048)148F.3.34 Target pulses (P044)149F.3.35 Target frequency (P045)150F.3.36 Spike rejection (P049)151F.3.37 False echo data (P081 to P088)152F.3.38 Clear false echoes (P089)153F.3.39 Transducer material (P970)154F.3.40 Poll address (D951)154F.3.41 Maximum temperature (P046)155F.3.42 Minimum temperature (P047)156F.3.43 Date (P003)156F.4 Monitoring and diagnostic parameters157F.4.1 Process value / Primary variable (PV) (D900)157F.4.2 Level / Secondary variable (SV) (D901)158F.4.3 Distance / Tertiary variable (TV) (D902)159F.4.4 Temperature / Fourth variable (FV) (D903)160F.4.5 % of output current (D905)161F.4.6 Current output (D906)162F.4.7 Distance (D910)163F.4.8 Echo size (D911)164F.4.9 Echo success (D912)165F.4.10 Target echoes (D913)166F.4.11 Speed of sound (D914)167F.4.12 Temperature for SoS calculation (D915)168F.4.13 Frequency (D916)169F.4.14 Threshold in use (D917)170F.4.15 Pulses in use (D918)171F.4.16 Transmit power (D919)172F.4.17 Model code (D949)173F.4.18 Hardware rev. (D952)173F.4.19 Software revision (D953)174F.4.20 Manufacturer (D960)175F.4.21 Unique device ID (D961)175F.4.22 HART revision (D962)176F.4.23 Transmitter specific command rev. (D963)177F.4.24 Preambles (D964)177F.4.25 Transmitter flags (D965)178F.4.26 Primary variable trend179Back Page182Size: 8.13 MBPages: 182Language: EnglishOpen manual