User ManualTable of ContentsINTRODUCTION5General Information5Features5Compatible Macurco Transducers5Specifications8Warranty8Return Instructions8Installation & Connection9Mounting the DVP-1209General Wiring Information9Main power Connection10Remote Sensor Connection10Relay Connection12Horn & Strobe Connection13Interfacing Macurco Sensors14Operation15Initial Operating Mode15Status Light Display15User Interface16Normal Status Display17ALARM Status Display17Warning Status Display18Trouble Status Display18Ventilation control19Zone Signal Display19Setting the System Configuration20System Menu21Configure System Submenu21Configure Sensors Submenu24Configure Relays, Horn & Strobe Submenu26Configure Horn Submenu27Configure Strobe Submenu28Configure Zones Submenu29Configure Signals Submenu32Troubleshooting36System Status Light Flashing36Input Channel Trouble36Internal Controller Board Trouble36Timed ventilation problem36No Power37LCD Display unreadable37Hold the MENU key for three (3) seconds.37Press the UP and DOWN cursor keys to change the LCD contrast.37Press any other key to exit the contrast-setting mode.37The Keypad does not respond (LCD shows KEYS LOCKED)37After a power failure37Figure 1-1 System Wiring Diagram6Figure 1-2 DVP-120 Internal View7Figure 2-1 Sensor Interface Connector10Figure 2-2 Relay Connector12Figure 2-3 Horn & Strobe Connector13Figure 3-1 Model Display15Figure 3-2 Warm-Up display15Figure 3-3 Keypad layout16Figure 3-4 Normal System Display17Figure 3-5 Sensor prompt17Figure 3-6 Alarm display17Figure 3-7 Alarm Silenced message18Figure 3-8 Warning display18Figure 3-9 Warning Silenced message18Figure 3-10 Trouble display18Figure 3-11 Trouble Silenced message19Figure 3-12 Zone Signal display19Figure 3-13 Zone Signal Silenced message19Figure 3-14 Hardware Summary20Figure 3-15 Save Configuration? Prompt20Figure 3-16 Set Time of Day21Figure 3-17 Enter Hours21Figure 3-18 Enter Minutes21Figure 3-19 Set Day of the week22Figure 3-20 Load Default Configuration22Figure 3-21 Enter Password23Figure 3-22 Password Prompt23Figure 3-23 Wrong Password Prompt23Figure 3-24 Sensor Summary24Figure 3-25 Sensor Type24Figure 3-26 Sensor’s Alarm Level24Figure 3-27 Sensor’s Warning Level25Figure 3-28 Sensor’s Range25Figure 3-29 Relay Summary26Figure 3-30 Relay Mode26Figure 3-31 Turn On Delay26Figure 3-32 Minimum on time26Figure 3-33 Horn Summary27Figure 3-34 Horn Mode27Figure 3-35 Horn Turn On Delay27Figure 3-36 Horn Minimum on time27Figure 3-37 Strobe Summary28Figure 3-38 Strobe Mode28Figure 3-39 Strobe Turn On Delay28Figure 3-40 Strobe Minimum on time28Figure 3-41 Zone Controls29Figure 3-42 Zone Group Type29Figure 3-43 Timer Days Selection30Figure 3-44 Start Time Selection30Figure 3-45 Stop Time Selection30Figure 3-46 Sensor Selection30Figure 3-47 Add/Remove sensor prompt30Figure 3-48 Rising Trip Point Entry31Figure 3-49 Falling Trip Point Entry31Figure 3-50 Sensor Mode Selection31Figure 3-51 Quorum Entry31Figure 3-52 Alarm Signals32Figure 3-53 Buzzer Alarm Signal32Figure 3-54 Horn Alarm Signal32Figure 3-55 Strobe Alarm Signal33Figure 3-56 Warning Signals33Figure 3-57 Buzzer Warning Signal33Figure 3-58 Horn Warning Signal33Figure 3-59 Strobe Warning Signal34Figure 3-60 Trouble Signals34Figure 3-61 Buzzer Trouble Signal34Figure 3-62 Horn Trouble Signal34Figure 3-63 Strobe Trouble Signal35Table 2-1 Main Power Connections10Table 2-2 Recommended Wire Gauge10Table 2-3 Connector to Sensor Channel Mapping11Table 2-4 Sensor Connectors: Channel and Pin Assignments11Table 2-5 Relay Interface Signals and Connector Assignments12Table 2-6 Horn & Strobe signals and Connector Assignments13Table 2-7 Wire gauge for Horn & Strobe functions13Table 2-8 Macurco Transducers14Size: 557 KBPages: 37Language: EnglishOpen manual